MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/ac7376

Медицинская библиотека · Physics in medicine and biology · 2022

TransDose: a transformer-based UNet model for fast and accurate dose calculation for MR-LINACs.

Xiao Fan, Cai Jiajun, Zhou Xuanru, Zhou Linghong, Song Ting, Li Yongbao

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Objective. To present a transformer-based UNet model (TransDose) for fast and accurate dose calculation for magnetic resonance-linear accelerators (MR-LINACs).Approach. A 2D fluence map from each beam was first projected into a 3D fluence volume and then fed into the TransDose model together with patient density volume and output predicted beam dose. The proposed TransDose model combined a 3D residual UNet with a transformer encoder, where convolutional layers extracted the volumetric spatial features, and the transformer encoder processed the long-range dependencies in a global space. Ninety-eight cases with four tumor sites (brain, nasopharynx, lung, and rectum) treated with fixed-beam intensity-modulated radiotherapy were included in the dataset; 78 cases were used for model training and validation; and 20 cases were used for testing. The ground-truth beam doses were calculated with Monte Carlo (MC) simulations within 1% statistical uncertainty and magnetic field strengthB = 1.5 T in the superior and inferior direction. Beam angles from the training and validation datasets were rotated 2-5 times, and doses were recalculated to augment the datasets.Results. The dose-volume histograms and indices between the predicted and MC doses showed good consistency. The average 3Dγ-passing rates (3%/2 mm, for dose regions above 10% of maximum dose) were 99.13 ± 0.89% (brain), 98.31 ± 1.92% (nasopharynx), 98.74 ± 0.70% (lung), and 99.28 ± 0.25% (rectum). The average dose calculation time, which included the fluence projection and model prediction, was less than 310 ms for each beam.Significance. We successfully developed a transformer-based UNet dose calculation model-TransDose in magnetic fields. Its accuracy and efficiency indicated its potential for use in online adaptive plan optimization for MR-LINACs.

Для цитирования: Xiao Fan, Cai Jiajun, Zhou Xuanru, Zhou Linghong, Song Ting, Li Yongbao. TransDose: a transformer-based UNet model for fast and accurate dose calculation for MR-LINACs.. Physics in medicine and biology. 2022. DOI: 10.1088/1361-6560/ac7376.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.