INTRODUCTION

This study aimed to evaluate rapid antigen detection (RAD) and rapid nucleic acid amplification tests (NAATs) to detect influenza virus (IV).

METHODS

The conventional RAD test (Quick Chaser Flu A, B: QC), using silver amplified immunochromatography (Quick Chaser Auto Flu A, B: QCA), as well as two NAATs (Xpert Xpress Flu/RSV: Xpert, cobas Influenza A/B & RSV: cobas) were evaluated using nasopharyngeal swabs from suspected cases of influenza. A reference method was performed using real-time reverse transcription polymerase chain reaction according to the manual of the Japanese National Institute of Infectious Disease (NIID).

RESULTS

From a total of 177 samples, 51 were positive according to the NIID assay. The kappa (κ) coefficient in Xpert and cobas for influenza A virus (IAV)/influenza B virus (IBV) was 1.00, which was the highest among the four detection assays. However, the κ coefficients in QC and QCA for IAV/IBV were 0.71-0.77 and 0.87-0.89, respectively. The sensitivities of the RAD tests were 41.7% in QC and 50.0% in QCA at < 6 h after onset, and 100.0% in both QC and QCA at 24-48 h after onset. The cycle threshold (Ct) values were significantly lower in the group in which all detection assays were positive for IAV.

CONCLUSIONS

Xpert and cobas have comparable analytical performances and are highly useful as influenza virus detection assays. QC and QCA could show false negatives frequently in the early stage of infection and when viral load is low.

Для цитирования: Sato Yuki, Nirasawa Shinya, Saeki Masachika, Yakuwa Yuki, Ono Mayumi, Kobayashi Ryo, Nakafuri Hirotaka, Murai Ryosei, Fujiya Yoshihiro, Kuronuma Koji, Takahashi Satoshi. Comparative study of rapid antigen testing and two nucleic acid amplification tests for influenza virus detection.. Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy. 2022. DOI: 10.1016/j.jiac.2022.04.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.