MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2013.12.013

Медицинская библиотека · Journal of cardiology · 2014

Novel dyssynchrony evaluation by M-mode imaging in left bundle branch block and the application to predict responses for cardiac resynchronization therapy.

Sakamaki Fumiko, Seo Yoshihiro, Atsumi Akiko, Yamamoto Masayoshi, Machino-Ohtsuka Tomoko, Kawamura Ryo, Yamasaki Hiro, Igarashi Miyako, Sekiguchi Yukio, Ishizu Tomoko, Aonuma Kazutaka

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To determine an appropriate M-mode method in assessing left ventricular (LV) dyssynchrony in left bundle branch block (LBBB), and to assess feasibility of the method to predict cardiac resynchronization therapy (CRT) responses.

METHODS AND

RESULTS

Fifty-one patients with LBBB were enrolled. Among them 31 patients underwent CRT. In addition to original septal to posterior wall motion delay (SPWMD), first peak-SPWMD was proposed as time of difference between the first septal displacement and the maximum displacement of the posterior. If an early septal point was not present, anatomical M-mode was used to visualize an early septal displacement spreading scan-area until inferoseptal wall. CRT responders were defined as LV end-systolic volume reduction (>15%) at 6 months after CRT. Twenty patients (65%) were identified as CRT responders. First peak-SPWMD in responders was significantly higher than those in nonresponders, although SPWMD did not differ between groups. Strong predicting ability of first peak-SPWMD was revealed (first peak-SPWMD: 80/90/83%; SPWMD: 35/100/58%), and area under the curve in receiver operating characteristic analysis of first peak-SPWMD (0.88) was significantly higher than that of SPWMD (0.61) (p<0.05).

CONCLUSION

In patients with LBBB, time differences between early septal and delayed displacement of posterolateral wall on M-mode images were the appropriate dyssynchrony parameter, and could improve the predictive ability for CRT responses.

Для цитирования: Sakamaki Fumiko, Seo Yoshihiro, Atsumi Akiko, Yamamoto Masayoshi, Machino-Ohtsuka Tomoko, Kawamura Ryo, Yamasaki Hiro, Igarashi Miyako, Sekiguchi Yukio, Ishizu Tomoko, Aonuma Kazutaka. Novel dyssynchrony evaluation by M-mode imaging in left bundle branch block and the application to predict responses for cardiac resynchronization therapy.. Journal of cardiology. 2014. DOI: 10.1016/j.jjcc.2013.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.