DOI 10.5935/abc.20130190

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2013

Mechanical dyssynchrony is similar in different patterns of left bundle-branch block.

Barretto Rodrigo Bellio de Mattos, Piegas Leopoldo Soares, Assef Jorge Eduardo, Melo Neto José Francisco, Resende Thiago Uchoa, Moreira Dalmo Antonio, Lebihan David Costa, França Francisco Faustino, Meneghelo Romeu Sérgio, Sousa Amanda Guerra Moraes Rego

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Left bundle-branch block (LBBB) and the presence of systolic dysfunction are the major indications for cardiac resynchronization therapy (CRT). Mechanical ventricular dyssynchrony on echocardiography can help identify patients responsive to CRT. Left bundle-branch block can have different morphologic patterns.

OBJECTIVE

To compare the prevalence of mechanical dyssynchrony in different patterns of LBBB in patients with left systolic dysfunction.

METHODS

This study assessed 48 patients with ejection fraction (EF) < 40% and LBBB consecutively referred for dyssynchrony analysis. Conventional echocardiography and mechanical dyssynchrony analysis were performed, interventricular and intraventricular, with ten known methods, using M mode, Doppler and tissue Doppler imaging, isolated or combined. The LBBB morphology was categorized according to left electrical axis deviation in the frontal plane and QRS duration > 150 ms.

RESULTS

The patients' mean age was 60 ± 11 years, 24 were males, and mean EF was 29% ± 7%. Thirty-two had QRS > 150 ms, and22, an electrical axis between -30º and +90º. Interventricular dyssynchrony was identified in 73% of the patients, while intraventricular dyssynchrony, in 37%-98%. Patients with QRS > 150 ms had larger left atrium and ventricle, and lower EF (p < 0.05). Left electrical axis deviation associated with worse diastolic function and greater atrial diameter. Interventricular and intraventricular mechanical dyssynchrony (ten methods) was similar in the different LBBB patterns (p = ns).

CONCLUSION

In the two different electrocardiographic patterns of LBBB analyzed, no difference regarding the presence of mechanical dyssynchrony was observed.

Для цитирования: Barretto Rodrigo Bellio de Mattos, Piegas Leopoldo Soares, Assef Jorge Eduardo, Melo Neto José Francisco, Resende Thiago Uchoa, Moreira Dalmo Antonio, Lebihan David Costa, França Francisco Faustino, Meneghelo Romeu Sérgio, Sousa Amanda Guerra Moraes Rego. Mechanical dyssynchrony is similar in different patterns of left bundle-branch block.. Arquivos brasileiros de cardiologia. 2013. DOI: 10.5935/abc.20130190.