MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.113.000753

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2013

Interplay of electrical wavefronts as determinant of the response to cardiac resynchronization therapy in dyssynchronous canine hearts.

Strik Marc, van Middendorp Lars B, Houthuizen Patrick, Ploux Sylvain, van Hunnik Arne, Kuiper Marion, Auricchio Angelo, Prinzen Frits W

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The relative contribution of electromechanical synchronization and ventricular filling to the optimal hemodynamic effect in cardiac resynchronization therapy (CRT) during adjustment of stimulation-timings is incompletely understood. We investigated whether optimal hemodynamic effect in CRT requires collision of pacing-induced and intrinsic activation waves and optimal filling of the left ventricle (LV).

METHODS AND

RESULTS

CRT was performed in dogs with chronic left bundle-branch block (n=8) or atrioventricular (AV) block (n=6) through atrial (A), right ventricular (RV) apex, and LV-basolateral pacing. A 100 randomized combinations of A-LV/A-RV intervals were tested. Total activation time (TAT) was calculated from >100 contact mapping electrodes. Mechanical interventricular dyssynchrony was determined as the time delay between upslopes of LV and RV pressure curves. Settings providing an increase in LVdP/dtmax (maximal rate of rise of left ventricular pressure) of ≥90% of the maximum LVdP/dtmax value were defined as optimal (CRTopt). Filling was assessed by changes in LV end-diastolic volume (EDV; conductance catheter technique). In all hearts, CRTopt was observed during multiple settings, providing an average LVdP/dtmax increase of ≈15%. In AV-block hearts, CRTopt exclusively depended on interventricular-interval and not on AV-interval. In left bundle-branch block hearts, CRTopt occurred at A-LV intervals that allowed fusion of LV-pacing-derived activation with right bundle-derived activation. In all animals, CRTopt occurred at settings resulting in the largest decrease in TAT and mechanical interventricular dyssynchrony, whereas LV EDV hardly changed.

CONCLUSIONS

In left bundle-branch block and AV-block hearts, optimal hemodynamic effect of CRT depends on optimal interplay between pacing-induced and intrinsic activation waves and the corresponding mechanical resynchronization rather than filling.

Для цитирования: Strik Marc, van Middendorp Lars B, Houthuizen Patrick, Ploux Sylvain, van Hunnik Arne, Kuiper Marion, Auricchio Angelo, Prinzen Frits W. Interplay of electrical wavefronts as determinant of the response to cardiac resynchronization therapy in dyssynchronous canine hearts.. Circulation. Arrhythmia and electrophysiology. 2013. DOI: 10.1161/circep.113.000753.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.