MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circheartfailure.113.000380

Медицинская библиотека · Circulation. Heart failure · 2013

Impact of QRS morphology and duration on outcomes after cardiac resynchronization therapy: Results from the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT).

Birnie David H, Ha Andrew, Higginson Lyall, Sidhu Kiran, Green Martin, Philippon François, Thibault Bernard, Wells George, Tang Anthony

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The impact of QRS morphology and duration on the effectiveness of cardiac resynchronization therapy (CRT) has been usually assessed separately. The interaction between these 2 simple ECG parameters and their effect on CRT has not been systematically assessed in a large-scale clinical trial.

METHODS AND

RESULTS

The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial showed that implantable cardioverter defibrillator-CRT was associated with a significant reduction in the primary end point of all-cause mortality or heart failure hospitalization. For this substudy, we excluded patients in atrial fibrillation and those with a previous pacemaker. All baseline ECGs were reviewed by a panel of 3 experienced electrocardiographers. A total of 1483 patients were included in this study. Of these, 1175 had left bundle-branch block (LBBB) and 308 had non-LBBB. In patients with LBBB receiving implantable cardioverter defibrillator-CRT, there was a reduction in the primary outcome and in each individual component of the primary outcome. Furthermore, there was continuous relationship between QRS duration and extent of benefit. In patients with non-LBBB and QRS ≥160 ms, the hazard ratio for the primary outcome was 0.52 (0.29-0.96; P=0.033); in patients with QRS <160 ms, the hazard ratio was 1.38 (0.88-2.14; P=0.155).

CONCLUSIONS

In patients with LBBB, there was a continuous relationship between broader QRS and greater benefit from implantable cardioverter defibrillator-CRT. However, our data do not support the use of implantable cardioverter defibrillator-CRT in patients with non-LBBB, especially when the QRS duration is <160 ms. There may be some delayed benefit when the QRS is ≥160 ms, but this needs further investigation.

CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00251251.

Для цитирования: Birnie David H, Ha Andrew, Higginson Lyall, Sidhu Kiran, Green Martin, Philippon François, Thibault Bernard, Wells George, Tang Anthony. Impact of QRS morphology and duration on outcomes after cardiac resynchronization therapy: Results from the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT).. Circulation. Heart failure. 2013. DOI: 10.1161/circheartfailure.113.000380.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.