Impact of the right ventricular lead position on clinical outcome and on the incidence of ventricular tachyarrhythmias in patients with CRT-D.

Kutyifa Valentina, Bloch Thomsen Poul Erik, Huang David T, Rosero Spencer, Tompkins Christine, Jons Christian, McNitt Scott, Polonsky Bronislava, Shah Amil, Merkely Bela, Solomon Scott D, Moss Arthur J, Zareba Wojciech, Klein Helmut U

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Data on the impact of right ventricular (RV) lead location on clinical outcome and ventricular tachyarrhythmias in cardiac resynchronization therapy with defibrillator (CRT-D) patients are limited.

OBJECTIVE

To evaluate the impact of different RV lead locations on clinical outcome in CRT-D patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy trial.

METHODS

We investigated 742 of 1089 CRT-D patients (68%) with adjudicated RV lead location enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy trial to evaluate the impact of RV lead location on cardiac events. The primary end point was heart failure or death; secondary end points included ventricular tachycardia (VT), ventricular fibrillation (VF), or death and VT or VF alone.

RESULTS

Eighty-six patients had the RV lead positioned at the RV septal or right ventricular outflow tract region, combined as nonapical RV group, and 656 patients had apical RV lead location. There was no difference in the primary end point in patients with nonapical RV lead location versus those with apical RV lead location (hazard ratio [HR] 0.98; 95% confidence interval [CI] 0.54-1.80; P = .983). Echocardiographic response to CRT-D was comparable across RV lead location groups (P > .05 for left ventricular end-diastolic volume, left ventricular end-systolic volume, and left atrial volume percent change). However, nonapical RV lead location was associated with significantly higher risk of VT/VF/death (HR 2.45; 95% CI 1.36-4.41; P = .003) and VT/VF alone (HR 2.52; 95% CI 1.36-4.65; P = .002), predominantly in the first year after device implantation. Results were consistent in patients with left bundle branch block.

CONCLUSIONS

In CRT-D patients, there is no benefit of nonapical RV lead location in clinical outcome or echocardiographic response. Moreover, nonapical RV lead location is associated with an increased risk of ventricular tachyarrhythmias, particularly in the first year after device implantation.

Для цитирования: Kutyifa Valentina, Bloch Thomsen Poul Erik, Huang David T, Rosero Spencer, Tompkins Christine, Jons Christian, McNitt Scott, Polonsky Bronislava, Shah Amil, Merkely Bela, Solomon Scott D, Moss Arthur J, Zareba Wojciech, Klein Helmut U. Impact of the right ventricular lead position on clinical outcome and on the incidence of ventricular tachyarrhythmias in patients with CRT-D.. Heart rhythm. 2013. DOI: 10.1016/j.hrthm.2013.08.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.