MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2013.04.013

Медицинская библиотека · Heart rhythm · 2013

Atrioventricular delay programming and the benefit of cardiac resynchronization therapy in MADIT-CRT.

Brenyo Andrew, Kutyifa Valentina, Moss Arthur J, Mathias Andrew, Barsheshet Alon, Pouleur Anne-Catherine, Knappe Dorit, McNitt Scott, Polonsky Bronislava, Huang David T, Solomon Scott D, Zareba Wojciech, Goldenberg Ilan

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The optimal atrioventricular pacing delay (AVD) in cardiac resynchronization therapy (CRT) remains to be determined.

OBJECTIVE

To determine whether programming CRT devices to short AVD (S-AVD) will improve clinical response secondary to greater reductions in dyssynchrony.

METHODS

The study population comprised 1235 patients with left bundle branch block enrolled in Multicenter Automatic Defibrillator Implantation Trial in Cardiac Resynchronization Therapy (MADIT-CRT). We assessed the relationship between AVD and outcomes. Patients programmed to S-AVD (median value of <120 ms; n = 337) vs long AVD (L-AVD; ≥120 ms; n = 390) were assessed for the end points of heart failure (HF) or death, death alone, and echocardiographic response to the CRT at 1-year follow-up. Outcomes were also compared to the left bundle branch block implantable cardioverter-defibrillator-only group (n = 508).

RESULTS

Multivariate analysis showed that patients programmed to S-AVD experienced a significant 33% (hazard ratio [HR] 0.67; 95% confidence interval [CI] 0.44-0.85; P = .037) reduction in the risk of HF or death and a 47% (HR 0.53; 95% CI 0.29-0.94; P = .031) reduction in death alone as compared with those programmed to L-AVD. Patients with CRT-programmed S-AVD and L-AVD experienced 63% (HR 0.37; 95% CI 0.26-0.53; P < .001) and 46% (HR 0.54; 95% CI 0.31-0.96; P < .001) reduction, respectively, in the risk of HF or death compared to patients with implantable cardioverter-defibrillator alone. At 1 year of follow-up, S-AVD vs L-AVD was associated with a greater reduction in left ventricular end-systolic volume (34.2% vs 30.8%; P = .002) along with a significantly greater improvement in dyssynchrony (22.3% vs 9.4%; P = .036).

CONCLUSIONS

Our findings indicate that in MADIT-CRT programming, the CRT AVD <120 ms was associated with a greater clinical and echocardiographic response to CRT.

Для цитирования: Brenyo Andrew, Kutyifa Valentina, Moss Arthur J, Mathias Andrew, Barsheshet Alon, Pouleur Anne-Catherine, Knappe Dorit, McNitt Scott, Polonsky Bronislava, Huang David T, Solomon Scott D, Zareba Wojciech, Goldenberg Ilan. Atrioventricular delay programming and the benefit of cardiac resynchronization therapy in MADIT-CRT.. Heart rhythm. 2013. DOI: 10.1016/j.hrthm.2013.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.