MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/qims-20-675

Медицинская библиотека · Quantitative imaging in medicine and surgery · 2021

Feasibility evaluation of amide proton transfer-weighted imaging in the parotid glands: a strategy to recognize artifacts and measure APT value.

Chen Yu, Wang Xiaoqi, Su Tong, Xu Zhentan, Wang Yunting, Zhang Zhuhua, Xue Huadan, Zhuo Zhizheng, Zhu Yuanli, Jin Zhengyu, Zhang Tao

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The feasibility and image quality of three-dimensional (3D) amide proton transfer (APT)-weighted (APTw) in parotid tumor lesions have not been well established in previous studies. This study aimed to evaluate the utility of APT imaging in parotid lesions and glands.

METHODS

Patients with parotid lesions received 3D turbo spin echo (TSE) APTw on a 3.0T scanner. Two radiologists, who were blinded to the clinical data, independently evaluated the APTw image quality using 4-point Likert scales (1= poor, 4= excellent) in terms of integrity and hyperintensity artifacts. An image quality selection protocol was built based on the two scores. Evaluable images (integrity score >1) and trustable images (integrity score >3 and hyperintensity artifacts score >2) were then enrolled for APTw value comparison between parotid lesions and glands.

RESULTS

Forty consecutive patients were included in this study. Four patients were excluded due to severe motion (n=3) or dental (n=1) artifacts, and 36 patients received the APT sequence. Among these, more parotid tumor lesions (34/36, 94.4%) than normal parotid glands (23/31, 74.2%) revealed excellent integrity scores (score =4) (P=0.034). Most parotid tumor lesions (24/34, 70.6%) and glands (16/28, 57.1%) revealed no or little hyperintensity artifacts for diagnosis (scores 3 and 4). APT values of parotid lesions and glands in the evaluable groups were 2.11%±1.15% and 1.60%±1.56%, respectively, and the difference was not significant (P=0.197). APT values of parotid lesions and glands in the trustable groups were 1.99%±1.18% and 1.03%±1.09%, respectively, and the difference was statistically significant (P=0.018).

CONCLUSIONS

3D APTw could be used to differentiate parotid tumors and normal parotid glands; however, the technology still needs to be improved to remove artifacts. In our study, most APTw images of tumor lesions in parotid glands had acceptable image quality, and these APTw images are feasible for diagnostic use.

Для цитирования: Chen Yu, Wang Xiaoqi, Su Tong, Xu Zhentan, Wang Yunting, Zhang Zhuhua, Xue Huadan, Zhuo Zhizheng, Zhu Yuanli, Jin Zhengyu, Zhang Tao. Feasibility evaluation of amide proton transfer-weighted imaging in the parotid glands: a strategy to recognize artifacts and measure APT value.. Quantitative imaging in medicine and surgery. 2021. DOI: 10.21037/qims-20-675.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.