INTRODUCTION
Diagnosis of acute coronary syndrome (ACS) is frequently a challenging task while immediate risk stratification remains crucial for the prompt implementation of appropriate therapy in this setting. The prolonged release pattern of both CK-MB mass and cardiac troponins makes it difficult to identify the origin of recent chest pain, thus a combination of early and later biomarkers might further facilitate the differential diagnosis. The study was designed to evaluate the efficacy of multi-marker approach using biochip array technology in identifying ACS shortly after the symptom onset.
MATERIAL AND
METHODS
The study group consisted of 42 patients suspected for ACS. Subjects were diagnosed as presenting with unstable angina (UA), non-ST-elevation myocardial infarction (NSTEMI) or ST-elevation myocardial infarction (STEMI). Biomarkers in the serum were determined twice: on admission (≤6 hours from the chest pain onset) and after next 6 hours. Cardiac troponin I was measured by routine sensitive automated assay (STAT cTnI) while other 6 cardiac markers (heart-fatty acid binding protein - H-FABP, myoglobin, glycogen phosphorylase BB, cTn I, CK-MB mass and carbonic anhydrase III) were assessed using biochip array technology.
RESULTS
STAT cTnI concentrations within 6 hours from the symptom onset were elevated over the 99(th) percentile for reference population in 83.3% of subjects but none reached the cut-off value for myocardial infarction. Instead, H-FABP demonstrated a very good efficacy in early detection of ACS (90.5%), better than myoglobin and CK-MB mass. Sensitivity of H-FABP calculated for NSTEMI/STEMI subjects reached 100%. The diagnostic efficacy of troponin, myoglobin and CK-MB mass assay markedly increased within 12 hours. It was only for the patients with UA that the cardiac panel was not efficient in the early stratification of risk.
CONCLUSIONS
A multi-marker strategy with H-FABP and highly sensitive troponin included enhances the early diagnosis and decision making process in patients with ACS. A new biochip cardiac array technology may serve as a powerful tool for ACS detection in the clinical practice.