MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/02841850802452083

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2008

Noninvasive coronary angiography with 64-channel multidetector computed tomography in patients with acute coronary syndrome.

Ulimoen G R, Gjønnaess E, Atar D, Dahl T, Stranden E, Sandbaek G

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography.

PURPOSE: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS).

MATERIAL AND

METHODS

MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard.

RESULTS

48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of > or =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%.

CONCLUSION

Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome.

Для цитирования: Ulimoen G R, Gjønnaess E, Atar D, Dahl T, Stranden E, Sandbaek G. Noninvasive coronary angiography with 64-channel multidetector computed tomography in patients with acute coronary syndrome.. Acta radiologica (Stockholm, Sweden : 1987). 2008. DOI: 10.1080/02841850802452083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.