MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/iembs.2009.5333867

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2009

Fuzzy logic based classification and assessment of pathological voice signals.

Aghazadeh Babak Seyed, Heris Hossein Khadivi

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In this paper an efficient fuzzy wavelet packet (WP) based feature extraction method and fuzzy logic based disorder assessment technique were used to investigate voice signals of patients suffering from unilateral vocal fold paralysis (UVFP). Mother wavelet function of tenth order Daubechies (d10) was employed to decompose signals in 5 levels. Next, WP coefficients were used to measure energy and Shannon entropy features at different spectral sub-bands. Consequently, using fuzzy c-means method, signals were clustered into 2 classes. The amount of fuzzy membership of pathological and normal signals in their corresponding clusters was considered as a measure to quantify the discrimination ability of features. A classification accuracy of 100 percent was achieved using an artificial neural network classifier. Finally, fuzzy c-means clustering method was used as a way of voice pathology assessment. Accordingly, fuzzy membership function based health index is proposed.

Для цитирования: Aghazadeh Babak Seyed, Heris Hossein Khadivi. Fuzzy logic based classification and assessment of pathological voice signals.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2009. DOI: 10.1109/iembs.2009.5333867.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.