DOI 10.1080/20002297.2021.1881361

Медицинская библиотека · Journal of oral microbiology · 2021

Aerosols modification with H2O2 reduces airborne contamination by dental handpieces.

Ionescu Andrei Cristian, Brambilla Eugenio, Manzoli Lamberto, Orsini Giovanna, Gentili Valentina, Rizzo Roberta

СтатьяПеревод пока не подготовлен

Аннотация

Objective

We designed an in vitro study to evaluate the efficiency of an 0.5 vol% hydrogen peroxide-based spray in reducing Coronavirus 229E spread during a conventional dental procedure.

Methods

A class III cabinet-like chamber was custom-built, using phantoms for both patient and operator. A suspension of HCoV-229E in artificial saliva having a similar viral load to SARS-CoV-2 asymptomatic patients was inoculated inside the patient's phantom mouth. A 10 s-lasting dental procedure was performed using an aerosol-generating air-turbine, with or without high-volume evacuation (HVE). The effect of 0.5 vol% H2O2 cooling spray in reducing viral loads was tested. Viral presence on the operator phantom was assessed by Real-Time quantitative PCR on the mask's outer surface, on the phantom's forehead, and inside its mouth.

Results

When the H2O2 cooling spray was used, as compared to the conventional spray, viral loads were significantly lower on all tested sites, falling below the detection limit. Viral loads did not significantly change in any tested site when HVE was used.

Conclusion

The use of 0.5 vol% H2O2 cooling spray by dental handpieces drastically reduced the possibility of coronaviruses spread during aerosol-generating dental procedures. This strategy deserves further consideration among the preventive measures to be adopted during the SARS-CoV-2 pandemic.

Для цитирования: Ionescu Andrei Cristian, Brambilla Eugenio, Manzoli Lamberto, Orsini Giovanna, Gentili Valentina, Rizzo Roberta. Aerosols modification with H2O2 reduces airborne contamination by dental handpieces.. Journal of oral microbiology. 2021. DOI: 10.1080/20002297.2021.1881361.