Медицинская библиотека · Cardiovascular intervention and therapeutics · 2016

Impact of stent platform on longitudinal stent deformation: an in vivo frequency domain optical coherence tomography study.

Yamada Ryotaro, Okura Hiroyuki, Kume Teruyoshi, Fukuhara Kenzo, Koyama Terumasa, Higa Tomitaka, Neishi Yoji, Yoshida Kiyoshi, Uemura Shiro

СтатьяПеревод пока не подготовлен

Аннотация

Recently, longitudinal coronary stent deformation has been highlighted as a possible cause of drug-eluting stent failure. Although bench tests and in vivo studies have demonstrated difference in longitudinal stent strength among the stents with different platforms, its clinical impact is still unknown. Furthermore, it is unknown if modified stent platform favorably affect the incidence of stent deformation. The aim of this study was to investigate the longitudinal deformation of the everolimus-eluting stents (EES) with different stent platforms by using frequency domain optical coherence tomography (FD-OCT). Seventy-eight lesions treated with EES (Xience Prime: n = 26, Promus element: n = 29, Promus premier: n = 23) were studied. After successful stent implantation, FD-OCT was performed and stent length was measured using three-dimensional reconstruction of the images in vivo. Percent longitudinal stent shortening (%SS) was defined as the in vivo stent length divided by nominal stent length. Longitudinal stent deformation was defined as  %SS > 10 %. Patients' and procedural characteristics were similar among 3 EESs. There was no difference in mean  %SS between Xience Prime, Promus Element and Promus Premier (1.0 ± 5.8, 2.9 ± 6.7 and 0.8 ± 3.7 %, p = 0.322). Incidence of the longitudinal stent deformation was significantly higher in Promus Element than the other stents (0, 13.8 and 0 %, p = 0.028). Incidence of longitudinal stent deformation was different between EESs with different stent platforms. Stent material, stent design and/or stent delivery balloon may affect longitudinal stent deformation.

Для цитирования: Yamada Ryotaro, Okura Hiroyuki, Kume Teruyoshi, Fukuhara Kenzo, Koyama Terumasa, Higa Tomitaka, Neishi Yoji, Yoshida Kiyoshi, Uemura Shiro. Impact of stent platform on longitudinal stent deformation: an in vivo frequency domain optical coherence tomography study.. Cardiovascular intervention and therapeutics. 2016. DOI: 10.1007/s12928-016-0403-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.