MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heliyon.2024.e38377

Медицинская библиотека · Heliyon · 2024

Comparing ergosterol identification by HPLC with fungal serology in human sera.

Lafi Ahmad Sh A, Tzar Mohd Nizam, Santhanam Jacinta, Huyop Fahrul

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ergosterol, a predominant sterol in fungal cell membranes, holds promise as a specific marker for detecting fungal presence in human samples. This study investigated the performance of ergosterol detection compared to serological tests in identifying the presence of fungi in human sera.

METHODS

Eighty-four non-duplicate human sera were analyzed by high performance liquid chromatography (HPLC) for ergosterol detection. Results were compared to serological tests for Aspergillus antigen, Candida antigen, Cryptococcus antigen, Aspergillus antibody and Candida antibody performed on the same patient sera.

RESULTS

Out of the 84 serum samples, 51 (60.7 %) were positive for ergosterol. Among the 33 serology-positive sera, 26 (78.8 %) were also ergosterol-positive. In contrast, 26 out of 51 (51 %) serology-negative sera (including 20 negative controls) tested negative for ergosterol. Seven out of 33 (21.2 %) serology-positive sera were ergosterol-negative, while 25 out of 51 (49 %) serology-negative sera were ergosterol-positive. Compared to serological tests, HPLC detection of ergosterol had a sensitivity of 78.8 %, specificity of 51 %, positive predictive value of 51 %, negative predictive value of 78.8 % and overall accuracy of 61.9 %.

CONCLUSIONS

Ergosterol detection may serve as a useful supplementary tool for identifying fungi in human sera, acting as a broad-spectrum diagnostic marker. However, further research with larger sample sizes and clinical comparisons is needed to validate these findings.

Для цитирования: Lafi Ahmad Sh A, Tzar Mohd Nizam, Santhanam Jacinta, Huyop Fahrul. Comparing ergosterol identification by HPLC with fungal serology in human sera.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e38377.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.