MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm10214913

Медицинская библиотека · Journal of clinical medicine · 2021

Good Metabolic Control in Children with Type 1 Diabetes Mellitus: Does Glycated Hemoglobin Correlate with Interstitial Glucose Monitoring Using FreeStyle Libre?

Porcel-Chacón Rocio, Antúnez-Fernández Cristina, Mora Loro Maria, Ariza-Jimenez Ana-Belen, Tapia Ceballos Leopoldo, Jimenez Hinojosa Jose Manuel, Lopez-Siguero Juan Pedro, Leiva Gea Isabel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Good metabolic control of Type 1 diabetes (T1D) leads to a reduction in complications. The only validated parameter for establishing the degree of control is glycated hemoglobin (HbA1c). We examined the relationship between HbA1c and a continuous glucose monitoring (CGM) system.

MATERIALS AND

METHODS

A cohort prospective study with 191 pediatric patients with T1D was conducted. Time in range (TIR), time below range (TBR), coefficient of variation (CV), number of capillary blood glucose tests, and HbA1c before sensor insertion and at one year of use were collected.

RESULTS

Patients were classified into five groups according to HbA1c at one year of using CGM. They performed fewer capillary blood glucose test at one year using CGM (-6 +/- 2, p < 0.0001). We found statistically significant differences in TIR between categories. Although groups with HbA1c < 6.5% and HbA1c 6.5-7% had the highest TIR (62.214 and 50.462%), their values were highly below optimal control according to CGM consensus. Groups with TBR < 5% were those with HbA1c between 6.5% and 8%.

CONCLUSIONS

In our study, groups classified as well-controlled by guidelines were not consistent with good control according to the CGM consensus criteria. HbA1c should not be considered as the only parameter for metabolic control. CGM parameters allow individualized targets.

Для цитирования: Porcel-Chacón Rocio, Antúnez-Fernández Cristina, Mora Loro Maria, Ariza-Jimenez Ana-Belen, Tapia Ceballos Leopoldo, Jimenez Hinojosa Jose Manuel, Lopez-Siguero Juan Pedro, Leiva Gea Isabel. Good Metabolic Control in Children with Type 1 Diabetes Mellitus: Does Glycated Hemoglobin Correlate with Interstitial Glucose Monitoring Using FreeStyle Libre?. Journal of clinical medicine. 2021. DOI: 10.3390/jcm10214913.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.