MedElevator Войти в исследования
← Поиск публикаций

DOI 10.20945/2359-3997000000405

Медицинская библиотека · Archives of endocrinology and metabolism · 2021

Flash glucose monitoring system: impact on glycemic control and body mass index in type 1 diabetes mellitus.

Sá Juliana Marques, Lopes Sara Campos, Barbosa Mariana, Barros Inês Ferreira, Santos Maria Joana

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Flash glucose monitoring (FGM) is increasingly used in type 1 diabetes mellitus (T1D) management. This study aimed to assess glycated hemoglobin (HbA1c) and body mass index (BMI) in the first year of FGM use in patients with T1D and to identify predictive factors of benefit associated with its use.

METHODS

Retrospective study of T1D patients, using FGM for ≥ 6 months and under intensive insulin therapy with multiple daily injections.

RESULTS

In 179 patients with a median (Md) age of 43.0 years (P25 31.0; P75 52.0) and disease duration of 18.0 years (P25 10.0; P75 28.0), initial HbA1c was 7.9% (P25 7.2; P75 8.8) and initial BMI was 24.0 kg/m2 (P25 21.9; P75 26.2). With FGM, HbA1c improved significantly to 7.6% (P25 7.0; P75 8.3) at 6 months and 7.7% (P25 6.95; P75 8.5) at 12 months (p < 0.05), with more patients with HbA1c < 7% (16.1% vs 22.5%) and fewer patients with HbA1c ≥ 8% (49.1% vs 35.8%) (p < 0.05). Initial HbA1c 8.0-8.9% (HR 1.886; 95% CI 1.321-2.450) and ≥ 9.0% (HR 3.108, 95% CI 2.454-3.761) predicted greater HbA1c reduction. BMI increased significantly, especially between 6 and 12 months (BMI Md 23.8 [P25 21.9; P75 26.2] kg/m2 and 24.0 [P25 22.0; P75 26.2] kg/m2, respectively) (p < 0.05). Overweight (HR 4.319, 95% CI 3.185-5.453) and obesity (HR 8.112, 95% CI 3.919-12.306) predicted greater weight gain.

CONCLUSION

FGM use was associated with significant improvement in HbA1c, mainly in patients with worse previous glycemic control. It was also associated with increased BMI, especially if baseline BMI ≥ 25 kg/m2, so weight control strategies should be emphasized.

Для цитирования: Sá Juliana Marques, Lopes Sara Campos, Barbosa Mariana, Barros Inês Ferreira, Santos Maria Joana. Flash glucose monitoring system: impact on glycemic control and body mass index in type 1 diabetes mellitus.. Archives of endocrinology and metabolism. 2021. DOI: 10.20945/2359-3997000000405.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.