MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0b013e31820846dd

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2011

Influence of motion smear on visual acuity in simulated infantile nystagmus.

Chung Susana T L, LaFrance Martin W, Bedell Harold E

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: In persons with infantile nystagmus (IN), visual acuity correlates with the duration of the foveation period of the nystagmus waveform, i.e., when the retinal image is on or near the fovea and moves with low velocity. In this study, we asked how acuity is affected by the non-foveating phases of the nystagmus waveform, when the velocity of retinal image motion is substantially higher.

METHODS

Visual acuity was measured in three normal observers for high contrast, four-orientation single T-stimuli, presented during image motion that simulated either the whole jerk-IN waveform (whole-waveform) or only the foveation periods of the IN waveform (foveation-only). Simulated foveation durations ranged from 20 to 120 ms. For both motion waveforms, we displayed the acuity target for different number of cycles to examine whether acuity benefits from multiple presentations of the stimulus.

RESULTS

As expected, visual acuity improves with longer simulated foveation durations in both the whole-waveform and foveation-only conditions. Acuity is consistently better (by ∼0.1 logarithm of the minimum angle of resolution) in the foveation-only than the whole-waveform condition, indicating that the high-velocity image motion during the simulated IN waveform has a detrimental effect. This difference in acuity between the two waveform conditions increases with the number of cycles, apparently because summation occurs across cycles in the foveation-only condition but not in the whole-waveform condition.

CONCLUSIONS

In normal observers, visual acuity in the presence of a simulated nystagmus waveform is limited not only by the duration of the foveation periods, but also by the non-foveating phases of the waveform. However, because persons with IN report little or no motion smear in association with their nystagmus, it remains unclear whether the rapid retinal image motion during the non-foveating phases of the nystagmus waveform generates a similar degradation of visual acuity in IN.

Для цитирования: Chung Susana T L, LaFrance Martin W, Bedell Harold E. Influence of motion smear on visual acuity in simulated infantile nystagmus.. Optometry and vision science : official publication of the American Academy of Optometry. 2011. DOI: 10.1097/opx.0b013e31820846dd.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.