Artificial intelligence for otosclerosis detection on temporal bone CT: a diagnostic study.

Koder Ahmet, Dinç Yunus Emre, Hancı Nur Banu, Erdem Oğuzhan, Yağız Recep, Astana Ekber Can, Hancı Nurseli

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Otosclerosis is a primary osteodystrophy of the otic capsule that causes conductive or mixed hearing loss. High-resolution computed tomography (HRCT) is the preferred imaging tool, but its sensitivity varies and depends on radiologist expertise. Artificial intelligence (AI) may improve diagnostic accuracy by identifying subtle features.

OBJECTIVE

To evaluate the diagnostic accuracy of a convolutional neural network (CNN) in detecting otosclerosis on temporal bone CT scans.

METHODS

This retrospective study included CT scans from 53 surgically confirmed otosclerosis patients and 36 healthy controls. After augmentation, the dataset comprised 74 otosclerosis and 74 control images. A CNN with three convolutional layers, dropout, and a fully connected dense layer was developed. Model performance was assessed using accuracy, sensitivity, specificity, precision, F1-score, and area under the receiver operating characteristic curve (AUC).

RESULTS

The CNN achieved 98% training and 87.5% maximum validation accuracy. In validation, sensitivity was 80.0%, specificity 84.6%, precision 85.7%, F1-score 82.8%, and AUC 0.847. Learning curves showed stable convergence without overfitting.

CONCLUSION AND SIGNIFICANCE: AI-based CT analysis demonstrated promising diagnostic performance in otosclerosis, especially in cases initially reported as normal. Integration of AI into otologic imaging may enhance diagnostic reliability, surgical planning, and patient management.

Для цитирования: Koder Ahmet, Dinç Yunus Emre, Hancı Nur Banu, Erdem Oğuzhan, Yağız Recep, Astana Ekber Can, Hancı Nurseli. Artificial intelligence for otosclerosis detection on temporal bone CT: a diagnostic study.. Acta oto-laryngologica. 2025. DOI: 10.1080/00016489.2025.2588812.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.