MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cpcardiol.2022.101426

Медицинская библиотека · Current problems in cardiology · 2022

Propensity-Weighted Comparison of Conventional Stented and Rapid-Deployment Aortic Bioprostheses.

D'Onofrio Augusto, Cibin Giorgia, Lorenzoni Giulia, Tessari Chiara, Bifulco Olimpia, Lombardi Valentina, Bergonzoni Emma, Evangelista Giuseppe, Pesce Rita, Taffarello Pierpaolo, Longinotti Lorenzo, Ponzoni Matteo, Gregori Dario, Gerosa Gino

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Aim of this study was to compare early clinical and hemodynamic outcomes of Intuity and ME bioprostheses. A propensity score weighting approach was performed. Preoperative variables were defined according to EuroSCORE criteria and postoperative complications according to VARC-2 definitions. We evaluated 375 patients who underwent SAVR with the 2 study devices. Intuity and ME were implanted in 252 (67.2%) and in 123 (32.8%) patients, respectively. There were no differences in terms of postoperative complications, including mortality (1% in each group; OR 0.46[0.05;4.21]). The incidence of pace-maker implantation was 6% and 5% in Intuity and ME groups, respectively (OR 0.53[0.27;1.07]). Intuity showed significantly lower gradients (Median mean gradients: 9mmHg vs 14mmHg, P<0.001), larger effective orifice area index (1.13cm2/m2 vs 1cm2/m2, P=0.007) and lower incidence of patient-prosthesis mismatch (7.1% vs 22.8%, P=0.006). The RD Intuity provides similar early clinical outcomes but shows significantly better hemodynamic performance compared to the ME valve.

Для цитирования: D'Onofrio Augusto, Cibin Giorgia, Lorenzoni Giulia, Tessari Chiara, Bifulco Olimpia, Lombardi Valentina, Bergonzoni Emma, Evangelista Giuseppe, Pesce Rita, Taffarello Pierpaolo, Longinotti Lorenzo, Ponzoni Matteo, Gregori Dario, Gerosa Gino. Propensity-Weighted Comparison of Conventional Stented and Rapid-Deployment Aortic Bioprostheses.. Current problems in cardiology. 2022. DOI: 10.1016/j.cpcardiol.2022.101426.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.