Clinical and neurocognitive outcomes after transcatheter aortic valve implantation (TAVI) with cerebral protection: initial experience with a novel dual-filter device in Southeast Asia.
Аннотация
INTRODUCTION
Transcatheter aortic valve implantation (TAVI) is increasingly performed in patients with severe aortic stenosis. A novel dual-filter system to reduce cerebral embolism during TAVI recently became available. We aimed to assess the feasibility, safety, and clinical and neurocognitive outcomes of TAVI with cerebral protection in Asian patients.
METHODS
40 consecutive patients undergoing TAVI with cerebral protection were enrolled. All procedures were performed via femoral access using the self-expanding Evolut R/PRO or Portico, or the balloon-expandable SAPIEN 3 bioprostheses. Baseline characteristics, procedural and clinical outcomes were recorded. Cognition was assessed at baseline and 30 days using the abbreviated mental test (AMT).
RESULTS
The mean age of the patients (75% male) was 76.4 ± 8.4 years. TAVI was uncomplicated in all patients. The filter device was successfully deployed in 38 (95.0%) patients without safety issues. There was no stroke or death at 30 days, and the survival rate at nine months was 95.0%. There was no overall cognitive change (baseline vs. 30-day AMT: 9.2 ± 1.1 vs. 9.0 ± 1.5, p = 0.12), and only 1 (2.5%) patient developed impaired cognition at 30 days. Patients with a decreased AMT score at 30 days were significantly older than those without (82.1 ± 4.5 vs. 74.4 ± 7.7 years, p = 0.019). All patients with decreased AMT scores were aged ≥ 76 years.
CONCLUSION
In this early Asian experience of TAVI under cerebral protection, the filter device was successfully deployed in 95% of patients, with 100% procedural success. There were no filter-related complications and no stroke or mortality at 30 days. Overall cognition was preserved, although increased age was associated with a decline in AMT score.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.