MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.30370

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Two-year clinical outcomes after successful transcatheter aortic valve implantation with balloon-expandable versus self-expanding valves: A subanalysis of the GALILEO trial.

Okuno Taishi, Dangas George D, Hengstenberg Christian, Sartori Samantha, Herrmann Howard C, de Winter Robert, Gilard Martine, Tchétché Didier, Möllmann Helge, Makkar Raj R, Baldus Stephan, De Backer Ole, Bendz Bjørn, Kini Annapoorna, von Lewinski Dirk, Mack Michael, Moreno Raúl, Schäfer Ulrich, Wöhrle Jochen, Seeger Julia, Snyder Clayton, Nicolas Johny, Tijssen Jan G P, Welsh Robert C, Vranckx Pascal, Valgimigli Marco, Mehran Roxana, Kapadia Samir, Sondergaard Lars, Windecker Stephan

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Midterm data comparing clinical outcomes after successful implantation of self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. We aimed to compare 2-year outcomes after successful transcatheter aortic valve implantation (TAVI) with the Edwards balloon-expandable or the Medtronic self-expanding THV.

METHODS

Two-year outcomes were analyzed according to the implanted THV in the GALILEO trial. Major adverse cardiac and cerebrovascular events (MACCE) was a composite of all-cause death or thromboembolic events including stroke, myocardial infarction, symptomatic valve thrombosis, systemic embolism, deep-vein thrombosis, or pulmonary embolism.

RESULTS

Among 1644 patients recruited in 136 centers across 16 countries between 2015 and 2018, 499 received a self-expanding and 757 patients received a balloon-expandable THV. Patients treated with a self-expanding THV were more likely to be female, and had higher surgical risk, lower hemoglobin levels, and more frequent valve-in-valve procedures than those with a balloon-expandable THV. After multivariable adjustment, there were no significant differences in major clinical outcomes between self-expanding versus balloon-expandable THV: MACCE (17.0% vs. 13.4%, adjusted-hazard ratios [HR] 1.18, 95% confidence intervals [CI]: 0.82-1.69); all-cause death (11.4% vs. 9.3%, adjusted-HR 1.26; 95% CI: 0.78-2.05); cardiovascular death (8.5% vs. 4.0%, adjusted-HR 1.53; 95% CI: 0.82-2.86), any stroke (5.1% vs. 3.7%, adjusted-HR 0.86; 95% CI: 0.43-1.73); major or life-threatening bleeding (5.9% vs. 6.8%, adjusted-HR 0.93; 95% CI: 0.53-1.63).

CLINICAL TRIAL REGISTRATION: https://www.

CLINICALTRIALS: gov. NCT02556203.

CONCLUSIONS

Two-year follow-up data from the GALILEO trial indicate that successful TAVI either with self-expanding or balloon-expandable THVs according to physician discretion did not show difference in rates of MACCE.

Для цитирования: Okuno Taishi, Dangas George D, Hengstenberg Christian, Sartori Samantha, Herrmann Howard C, de Winter Robert, Gilard Martine, Tchétché Didier, Möllmann Helge, Makkar Raj R, Baldus Stephan, De Backer Ole, Bendz Bjørn, Kini Annapoorna, von Lewinski Dirk, Mack Michael, Moreno Raúl, Schäfer Ulrich, Wöhrle Jochen, Seeger Julia, Snyder Clayton, Nicolas Johny, Tijssen Jan G P, Welsh Robert C, Vranckx Pascal, Valgimigli Marco, Mehran Roxana, Kapadia Samir, Sondergaard Lars, Windecker Stephan. Two-year clinical outcomes after successful transcatheter aortic valve implantation with balloon-expandable versus self-expanding valves: A subanalysis of the GALILEO trial.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2022. DOI: 10.1002/ccd.30370.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.