m+Medelevator.RU
← Поиск публикаций
Archivos de cardiologia de Mexico · 2023

Relationship of the T-wave Tpeak-Tend interval with conduction system disorders in arterial hypertension.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Candia José C, Centurión Osmar A, Alderete José F, Torales Judith M, Aquino Nelson J, Miño Luis M, Scavenius Karina E, García Laura B, Cáceres Cristina, Sequeira Orlando J, Chávez Christian O, Martínez Jorge E, Lovera Oscar A, Galeano E Javier

Аннотация

PURPOSE: The Tpeak-Tend interval of the T wave has emerged as a new electrocardiographic marker of increased transmural dispersion of ventricular repolarization. We aimed to determine the presence of cardiac conduction system disorders in patients with systemic arterial hypertension (SAH) who have altered Tpeak-Tend interval of the T wave.

METHODS: The 67 patients with SAH were divided into two groups. Those with prolonged (≥ 77 ms) Tpeak-Tend intervals, 21 (31%) patients were in the study group. Those with normal (< 77 ms) Tpeak-Tend intervals, 46 (69%) patients were in the control group. Alteration of ventricular repolarization manifested as a prolongation of the Tpeak-Tend interval was detected by computerized electrocardiographic analysis tools.

RESULTS: The median value of QRS complex duration was significantly wider in the study group as compared to the control group (110 ± 12 ms vs. 94 ± 8 ms p < 0.001). There was a significantly greater incidence of left anterior hemiblock in the study group (14% vs. 0% p < 0.04). The median value of the QTc interval was significantly greater in the study group (440 ± 26 vs. 422 ± 15 p < 0.01). There was a significantly greater incidence of patients with prolonged QTc interval in the study group (33% vs. 11% p < 0.02). The median value of the Tpeak-Tend interval was significantly greater in the study group (84 ± 5 ms vs. 65 ± 4 ms p < 0.001), as well as, the Tpeak-Tend/QTc ratio in the study group (0.19 ± 0.1 vs. 0.16 ± 0.1 p < 0.001).

CONCLUSION: There is a significantly greater ventricular repolarization disorders and abnormalities of the cardiac conduction system in SAH patients who possess altered Tpeak-Tend interval of the T wave.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты