m+Medelevator.RU
← Поиск публикаций
Thrombosis and haemostasis · 2010

Fibrin presence within aortic valves in patients with aortic stenosis: association with in vivo thrombin generation and fibrin clot properties.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Natorska Joanna, Marek Grzegorz, Hlawaty Marta, Sadowski Jerzy, Tracz Wieslawa, Undas Anetta

Аннотация

A role of coagulation in the pathogenesis of aortic stenosis (AS) is unknown. The aim of this study was to investigate the fibrin (Fn) presence and its determinants in calcified stenotic aortic valve leaflets. Twenty-one patients with dominant AS and 17 well-matched patients with dominant aortic insufficiency (AI) undergoing aortic valve replacement were studied. Immunofluorescence analysis was performed on decalcified leaflets using antibodies against human Fn and tissue factor (TF). Fn-positive (41.4%) and TF-positive (25.3%) areas were increased in AS valves compared with AI valves (7.9% and 5.9%, respectively, both p<0.001). Patients with AS had elevated plasma D-dimer (236.4 ± 28 ng/ml, p=0.002) and prothrombin fragment 1+2 (F1.2) (261.7 ± 27.1 pM, p=0.005) compared to AI subjects (142.8 ± 10 ng/ml and 131.2 ± 1.3 pM, respectively). In AS patients Fn-positive areas correlated with TF-positive areas (r=0.68, p=0.0005), D-dimer (r=0.45, p=0.018), F1.2 (r=0.64, p=0.002), the time required for plasma fibrin clot formation (r=0.44, p=0.015) and maximum absorbance of fibrin clots (r=-0.38, p<0.0001), but not with clot permeability or lysis time. Thickness of Fn layer within AS valves was associated with maximum transvalvular gradient (r =0.41, p=0.048). Patients with maximal gradient above 75 mmHg (n=11) showed significant associations between Fn-positive area and both maximal (r =0.63) and mean (r =0.67) transvalvular gradients. Large fibrin amounts, mostly co-localised with TF, are present within the valve leaflets of patients with advanced AS. In vivo thrombin generation and fibrin clot formation are associated with the extent of Fn presence within leaflets, which might contribute to the AS progression.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты