MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2010.06.021

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2010

The feasibility of velocity vector imaging by transesophageal echocardiography for assessment of elastic properties of the descending aorta in aortic valve disease.

Petrini Johan, Yousry Mohamed, Rickenlund Anette, Liska Jan, Hamsten Anders, Eriksson Per, Franco-Cereceda Anders, Caidahl Kenneth, Eriksson Maria J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Velocity vector imaging (VVI) is a novel two-dimensional speckle-based imaging technique for evaluation of tissue deformation. The aim of this study was to determine the feasibility and variability of VVI for the assessment of aortic strain, distensibility, and stiffness in patients with aortic valve disease.

METHOD: Eighty-five patients (mean age 66 +/- 11 years) with aortic stenosis (AS) or aortic regurgitation (AR) were examined in the operating room before the operation using transesophageal echocardiography (TEE). The two-dimensional short-axis images and M-mode recordings of the descending aorta were acquired simultaneously with the invasive blood pressure measurement in the radial artery. The TEE images were analyzed off-line using VVI software.

RESULTS

In comparison with patients with AS, patients with AR displayed significantly higher circumferential strain (7.6% +/- 4.5% vs. 3.7% +/- 1.9%, P < .001) and distensibility (27.1 +/- 12.8 kPa(-1)10(-3) vs. 17.2 +/- 7.2 kPa(-1)10(-3), P < .001) by VVI and distensibility (32.8 +/- 16.7 kPa(-1)10(-3) vs. 21.7 +/- 10.6 kPa(-1)10(-3), P < .004) by M-mode. Stiffness was higher in AS than AR, as measured by VVI (13.3 +/- 6.0 vs. 10.5 +/- 6.0, P < .01) and M-mode (11.2 +/- 6.1 vs. 10.4 +/- 9.1, P < .048). The correlations between VVI and M-mode distensibility (r = 0.84) and stiffness (r = 0.84) were both highly significant (P < .0001). The VVI strain measurements showed low inter- and intraobserver variability with intraclass correlations greater than 0.95 and coefficients of variation less than 10%.

CONCLUSION

VVI-derived strain, distensibility, and stiffness differ significantly between AR and AS and correlate strongly with the corresponding M-mode-derived parameters. VVI is a feasible method for the assessment of the elastic properties of the descending aorta with low variability and has the advantage of incorporating the entire aortic wall circumference in the analysis, consequently accounting for local variations in the elastic properties of the aorta.

Для цитирования: Petrini Johan, Yousry Mohamed, Rickenlund Anette, Liska Jan, Hamsten Anders, Eriksson Per, Franco-Cereceda Anders, Caidahl Kenneth, Eriksson Maria J. The feasibility of velocity vector imaging by transesophageal echocardiography for assessment of elastic properties of the descending aorta in aortic valve disease.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2010. DOI: 10.1016/j.echo.2010.06.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.