OBJECTIVES

This study sought to describe a method of paravalvular leak closure using a purpose-specific occlusion device.

BACKGROUND

Transcatheter closure of paravalvular leaks has been hampered by technical challenges, the limitations of available imaging modalities, and the lack of closure devices specifically designed for this purpose.

METHODS

Patients with severe symptomatic paravalvular regurgitation at high risk for repeat surgery underwent transcatheter leak closure. Both left ventricular puncture and retrograde transfemoral approaches were used with fluoroscopic and 3-dimensional transesophageal guidance. A purpose-specific occluder (Vascular Plug III, AGA Medical Corp., Plymouth, Minnesota) was used.

RESULTS

Five patients with severe prosthetic mitral and aortic paravalvular leaks underwent attempted closure. Implantation of the device was successfully accomplished in all. In 1 patient, the plug interfered with closure of a mechanical valve leaflet and was removed and replaced with an alternate device. Complications included pericardial bleeding in 2 patients with a transapical approach. There was no procedural mortality. At a median follow-up of 191 days (interquartile range [IQR] 169 to 203 days) all patients were alive. New York Heart Association functional class fell from 4 (IQR 3 to 4) to 2 (IQR 2 to 3), hemoglobin rose from 89 g/l (IQR 87 to 108 g/l) to 115 g/l (IQR 104 to 118 g/l), creatinine fell from 109 micromol/l (IQR 106 to 132 micromol/l) to 89 micromol/l (IQR 89 to 126 micromol/l). Median echocardiographic follow-up at 58 days (IQR 56 to 70 days) reported residual regurgitation to be reduced from grade 4 to grade 2 (IQR 1.5 to 2.25).

CONCLUSIONS

Closure of mitral and aortic prosthetic paravalvular leaks with the Vascular Plug III using either a transapical (mitral) or a retrograde (aortic) approach appears promising.

Для цитирования: Nietlispach Fabian, Johnson Mark, Moss Robert R, Wijesinghe Namal, Gurvitch Ronen, Tay Edgar L W, Thompson Christopher, Webb John G. Transcatheter closure of paravalvular defects using a purpose-specific occluder.. JACC. Cardiovascular interventions. 2010. DOI: 10.1016/j.jcin.2010.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.