MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2010.05.018

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2010

Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.

Pak Sang-Woo, Uriel Nir, Takayama Hiroo, Cappleman Sarah, Song Robert, Colombo Paolo C, Charles Sandy, Mancini Donna, Gillam Linda, Naka Yoshifumi, Jorde Ulrich P

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Left ventricular assist devices (LVADs) are increasingly used as long-term therapy for end-stage heart failure patients. We compared the prevalence of aortic insufficiency (AI) after HeartMate II (HMII) vs HeartMate XVE (HMI) support and assessed the role of aortic root diameter and aortic valve opening in the development of AI.

METHOD: Pre-operative and post-operative echocardiograms of 93 HMI and 73 HMII patients who received implants at our center between January 2004 and September 2009 were retrospectively reviewed. After excluding patients with prior or concurrent surgical manipulation of the aortic valve, with baseline AI, or without baseline echoes, 67 HMI and 63 HMII patients were studied. AI was deemed significant if mild to moderate or greater. Pathology reports were reviewed for 77 patients who underwent heart transplant.

RESULTS

AI developed in 4 of 67 HMI (6.0%) and in 9 of 63 HMII patients (14.3%). The median times to AI development were 48 days for HMI patients and 90 days for HMII patients. For patients who remained on device support at 6 and 12 months, freedom from AI was 94.5% and 88.9% in HMI patients and 83.6% and 75.2% in HMII patients (log rank p = 0.194). Aortic root diameters, as determined by echocardiography for the patients with AI, trended to be larger at baseline (3.43 ± 0.43 vs 3.15 ± 0.40; p = 0.067) and follow-up (3.58 ± 0.54 vs 3.29 ± 0.50; p = 0.130) compared with those who did not have AI. Aortic root circumferences were assessed directly by a pathologist in those patients who underwent transplant and were significantly larger in HMII patients who had developed AI compared with those patients who did not (8.44 ± 0.89 vs 7.36 ± 1.02 cm; p = 0.034). Lastly, AI was more common in patients whose aortic valve did not open (11 of 26 vs 1 of 14; p = 0.03).

CONCLUSION

Aortic insufficiency occurs frequently in patients who receive continuous-flow support with a HMII LVAD, and may be associated with aortic root diameter enlargement and aortic valve opening. These findings warrant a more thorough preoperative patient evaluation and additional studies to investigate the factors, that may be associated with AI development.

Для цитирования: Pak Sang-Woo, Uriel Nir, Takayama Hiroo, Cappleman Sarah, Song Robert, Colombo Paolo C, Charles Sandy, Mancini Donna, Gillam Linda, Naka Yoshifumi, Jorde Ulrich P. Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2010. DOI: 10.1016/j.healun.2010.05.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.