MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ahj.2010.02.030

Медицинская библиотека · American heart journal · 2010

Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantation.

Gotzmann Michael, Lindstaedt Michael, Bojara Waldemar, Mügge Andreas, Germing Alfried

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This prospective study was designed to evaluate the hemodynamic results of transcatheter aortic valve implantation (TAVI) with the CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) and the effects on left ventricular function.

METHODS

From June 2008 to June 2009, consecutive patients with severe symptomatic aortic valve stenosis (aortic valve area <1 cm(2)) and the indication for TAVI were included. Aortic valve prosthesis was inserted retrograde. Examinations of study patients were performed before, 30 days, and 6 months after TAVI and comprised measurement of B-type natriuretic peptide and echocardiography. Severe prosthesis-patient mismatch was defined as an indexed effective aortic valve area < or =0.65 cm(2)/m(2).

RESULTS

In 39 patients, follow-up examinations were performed after TAVI. Severe prosthesis-patient mismatch seldom occurred (n = 1), but mild to moderate aortic valve regurgitation due to paravalvular leaks was common (n = 24, 62%). After 6 months, left ventricular mass index declined (158 +/- 46 vs 138 +/- 45 g/m(2), P = .001), and peak early diastolic mitral annular velocity (E') and peak systolic mitral annular velocity (S') increased (P = .004 and P < .001, respectively). B-type natriuretic peptide levels decreased (744 +/- 708 at baseline vs 367 +/- 273 at 30 days, P = .003, 279 +/- 186 pg/mL at 6 months, P = .001). Left ventricular diameters and ejection fraction remained unchanged.

CONCLUSION

Despite the high incidence of paravalvular regurgitation after TAVI, hemodynamic results were favorable. Furthermore, TAVI had positive effects on left ventricular remodeling and improved neurohormonal activity, myocardial hypertrophy, and diastolic function.

Для цитирования: Gotzmann Michael, Lindstaedt Michael, Bojara Waldemar, Mügge Andreas, Germing Alfried. Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantation.. American heart journal. 2010. DOI: 10.1016/j.ahj.2010.02.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.