MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2009.11.010

Медицинская библиотека · JACC. Cardiovascular interventions · 2010

Procedural and mid-term results in patients with aortic stenosis treated with implantation of 2 (in-series) CoreValve prostheses in 1 procedure.

Gerckens Ulrich, Latsios George, Mueller Ralf, Buellesfeld Lutz, John Daniel, Yuecel Seyrani, Sauren Barthel, Felderhof Thomas, Iversen Stein, Grube Eberhard

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to assess post-procedural and mid-term outcome of patients, in which a second "in-series" CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) was implanted during the same procedure.

BACKGROUND

Because of the increasing number of patients implanted with CoreValves, the need for management of special complications has emerged. A misplaced prosthesis can be corrected by various maneuvers. An option is to pull the valve out of the aortic annulus into the ascending aorta or beyond and position a second one (in series).

METHODS

Out of 277 patients who underwent CoreValve implantation with the 18-F device in our institution, we had to implant a second prosthesis (due to severe aortic regurgitation or dislocation of the first one) in 9 (3.2%). Immediate post-procedural as well as mid-term follow-up data (5 to 20 months, mean 10.6 +/- 6 months, total 95 patient-months) were collected for analysis.

RESULTS

All implantations of the second device were successful, resulting in elimination of the gradient (mean gradient 43.1+/-4.0 mm Hg before to 7.0 +/- 1.1 mm Hg after implantation). There was no final aortic regurgitation grade >or=2+. The extra-anatomically placed first prosthesis (ascending aorta, n = 8; abdominal aorta, n = 1) did not cause any clinical sequelae or gradients. During mid-term follow-up, none of the 18 prostheses showed any sign of malfunction. Specifically, there were no signs of valve migration or of worsening paravalvular regurgitation. No case of valve thrombosis was documented.

CONCLUSIONS

A second CoreValve can be safely and effectively implanted in an in-series manner, without periprocedural complications. No problems arose on mid-term follow-up, ranging up to 20 months.

Для цитирования: Gerckens Ulrich, Latsios George, Mueller Ralf, Buellesfeld Lutz, John Daniel, Yuecel Seyrani, Sauren Barthel, Felderhof Thomas, Iversen Stein, Grube Eberhard. Procedural and mid-term results in patients with aortic stenosis treated with implantation of 2 (in-series) CoreValve prostheses in 1 procedure.. JACC. Cardiovascular interventions. 2010. DOI: 10.1016/j.jcin.2009.11.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.