OBJECTIVES

The aim of this study was to assess the influence of amount and distribution of calcifications of the aortic valve and the left ventricular outflow tract on the acute procedural outcome of patients undergoing transcatheter aortic valve implantation (TAVI).

BACKGROUND

Transcatheter aortic valve implantation is a new percutaneous technique especially for elderly, high-risk patients with significant aortic valve stenosis (AS). After TAVI, post-interventional paravalvular aortic regurgitations (PAR) can occur, which is believed to be related partially to valve calcifications.

METHODS

We prospectively analyzed 100 symptomatic patients with severe AS scheduled for TAVI with the CoreValve ReValving (Medtronic, Minneapolis, Minnesota) prosthesis. In all patients, a native and contrast-enhanced multislice cardiac computed tomography was performed pre-interventionally. Calcification load of the valve and the adjacent outflow tract was estimated by the Agatston Score (AgS), and the amount and distribution of calcification was semi-quantitatively assessed and graded on a 1 to 4 scale (device "landing zone" calcification score [DLZ-CS]). Aortography was performed to evaluate the PAR pre-interventionally, after initial device release (PAR0) and after termination of the procedure (PAR1). Transthoracic echocardiography was performed 2 weeks after implantation (PAR2).

RESULTS

The AgS and DLZ-CS showed a significant correlation with the grade of PAR0 (AgS: r = 0.329, p = 0.001; DLZ-CS: r = 0.356, p < 0.001), PAR1 (AgS: r = 0.254, p = 0.011; DLZ-CS: r = 0.240, p = 0.016), and PAR2 (AgS: r = 0.341, p = 0.001; DLZ-CS: r = 0.300, p = 0.002). Both scores (AgS and DLZ-CS) showed a significant positive correlation (r = 0.858, p < 0.001).

CONCLUSIONS

Calcification in the CoreValve device "landing zone" shows a significant positive correlation to PAR after TAVI. Furthermore, the need for "second maneuvers" (i.e., post-dilation after initial device release) can be predicted by these calcification scores (AgS and DLZ-CS).

Для цитирования: John Daniel, Buellesfeld Lutz, Yuecel Seyrani, Mueller Ralf, Latsios Georg, Beucher Harald, Gerckens Ulrich, Grube Eberhard. Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis.. JACC. Cardiovascular interventions. 2010. DOI: 10.1016/j.jcin.2009.11.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.