MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/emermed-2021-211823

Медицинская библиотека · Emergency medicine journal : EMJ · 2022

Evaluation of initial shockable rhythm as an indicator of short no-flow time in cardiac arrest: a national registry study.

Shibahashi Keita, Sugiyama Kazuhiro, Ishida Takuto, Hamabe Yuichi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The duration from collapse to initiation of cardiopulmonary resuscitation (no-flow time) is one of the most important determinants of outcomes after out-of-hospital cardiac arrest (OHCA). Initial shockable cardiac rhythm (ventricular fibrillation or ventricular tachycardia) is reported to be a marker of short no-flow time; however, there is conflicting evidence regarding the impact of initial shockable cardiac rhythm on treatment decisions. We investigated the association between initial shockable cardiac rhythm and the no-flow time and evaluated whether initial shockable cardiac rhythm can be a marker of short no-flow time in patients with OHCA.

METHODS

Patients aged 18 years and older experiencing OHCA between 2010 and 2016 were selected from a nationwide population-based Japanese database. The association between the no-flow time duration and initial shockable cardiac rhythm was evaluated. Diagnostic accuracy was evaluated using the sensitivity, specificity and positive predictive value.

RESULTS

A total of 177 634 patients were eligible for the analysis. The median age was 77 years (58.3%, men). Initial shockable cardiac rhythm was recorded in 11.8% of the patients. No-flow time duration was significantly associated with lower probability of initial shockable cardiac rhythm, with an adjusted OR of 0.97 (95% CI 0.96 to 0.97) per additional minute. The sensitivity, specificity and positive predictive value of initial shockable cardiac rhythm to identify a no-flow time of <5 min were 0.12 (95% CI 0.12 to 0.12), 0.88 (95% CI 0.88 to 0.89) and 0.35 (95% CI 0.34 to 0.35), respectively. The positive predictive values were 0.90, 0.95 and 0.99 with no-flow times of 15, 18 and 28 min, respectively.

CONCLUSIONS

Although there was a significant association between initial shockable cardiac rhythm and no-flow time duration, initial shockable cardiac rhythm was not reliable when solely used as a surrogate of a short no-flow time duration after OHCA.

Для цитирования: Shibahashi Keita, Sugiyama Kazuhiro, Ishida Takuto, Hamabe Yuichi. Evaluation of initial shockable rhythm as an indicator of short no-flow time in cardiac arrest: a national registry study.. Emergency medicine journal : EMJ. 2022. DOI: 10.1136/emermed-2021-211823.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.