MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics16020230

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2026

Endoscopic Ultrasound-Lavage Technique for Pancreatic Cancer: An In Vivo Pilot Study.

Abe Takahiro, Kato Masayuki, Shimamoto Nana, Komori Tomotaro, Matsumoto Naoki, Akasu Takafumi, Chiba Masafumi, Nakano Masanori, Isshi Kimio, Torisu Yuichi, Sumiyama Kazuki

СтатьяПеревод пока не подготовлен

Аннотация

Background

Pancreatic cancer (PC) has a very poor 5-year survival and prognosis. Even when CT or MRI shows no metastasis, staging laparoscopy(SL) still detects tiny peritoneal deposits in 20-30% of patients, making them ineligible for surgery. SL is invasive, requiring general anesthesia and substantial resources. Endoscopic ultrasound (EUS) allows the observation of the bile ducts, pancreas, and abdominal cavity, and EUS-guided fine-needle aspiration (EUS-FNA) is essential for pathological diagnosis. Reports on using EUS to perform peritoneal lavage cytology are currently not available. We hypothesized that combining EUS-FNA with peritoneal lavage (EUS-lavage technique; EUS-LT) could enhance staging accuracy and avoid unnecessary surgical procedures.

Methods

Ten in vivo porcine models underwent EUS-LT. Using a 19G FNA needle, 800 mL saline was instilled into the intraperitoneal cavity and then recovered. Two refinements were introduced sequentially: an ENBD catheter with additional side holes and, subsequently, a side-hole introducer (EndoSheather) that eliminated balloon dilation. The primary endpoint was procedural success. Secondary endpoints included safety, complications, recovered volume, duration of endoscopic procedure, and time required to instill 800 mL. Nonparametric tests compared outcomes across iterations.

Results

Ten-model porcine in vivo model series were included, and all procedures were successful. No device malfunctions or unanticipated technical failures; one minor mucosal injury during saline injection resolved after re-puncture. The average procedure time was 31.1 min. Stepwise refinements shortened procedure and infusion times and increased recovered volume. Recovered volume approached the instilled amount in later cases, indicating efficient performance.

Conclusions

In this ten-model in vivo series, EUS-LT demonstrated technical feasibility and short-term safety.

Для цитирования: Abe Takahiro, Kato Masayuki, Shimamoto Nana, Komori Tomotaro, Matsumoto Naoki, Akasu Takafumi, Chiba Masafumi, Nakano Masanori, Isshi Kimio, Torisu Yuichi, Sumiyama Kazuki. Endoscopic Ultrasound-Lavage Technique for Pancreatic Cancer: An In Vivo Pilot Study.. Diagnostics (Basel, Switzerland). 2026. DOI: 10.3390/diagnostics16020230.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.