MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4022/jafib.20200474

Медицинская библиотека · Journal of atrial fibrillation · 2021

Rate Control Versus Rhythm Control in Patients with Left Ventricular Assist Devices and Atrial Fibrillation.

L Gilge Jasen, Ahmed Asim, A Clark Bradley, Morris Kathleen, Yavar Zubin, Beaudrie Nicolas, Whitler Cameron, Husain Mahera, S Padanilam Mathew, J Patel Parin, N Prystowsky Eric, K Ravichandra Ashwinn

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Atrial fibrillation (AF) is a common comorbidity in patients with left ventricular assist devices (LVAD) with no defined guideline treatment strategy of rate versus rhythm control. The purpose of this study is to determine the effects of rate versus rhythm control for AF on the outcomes of patients with LVAD at our institution.

METHODS

Consecutive patients who underwent LVAD implantation at St Vincent Hospital from January 1, 2015 to December 31, 2017 were retrospectively evaluated. Patients with AF were identified and divided into rate control or rhythm control groups. The primary outcome evaluated was a composite of death, heart failure admission, gastrointestinal bleed, ventricular tachycardia, cerebrovascular accident, hemolysis, and pump thrombosis. Secondary outcomes included the individual variables from the primary outcome.

RESULTS

Out of 201 patients that underwent LVAD implantation, 81 had AF after implantation and were included with a median follow-up period of 384 days. The rate control group (n = 31; 38%) and the rhythm control group (n = 51; 62%) had no difference in composite outcomes (61% vs 59%, p = 0.83). When taken individually there was no difference in outcomes between the two groups. Thirteen patients underwent electrical cardioversion and successful conversion to normal sinus rhythm occurred in 71% of cases with a 60% recurrence rate.

CONCLUSIONS

There was no difference in primary outcome between rate and rhythm control groups. These data suggest that maintenance of sinus rhythm may not be necessary in all patients with LVAD.

Для цитирования: L Gilge Jasen, Ahmed Asim, A Clark Bradley, Morris Kathleen, Yavar Zubin, Beaudrie Nicolas, Whitler Cameron, Husain Mahera, S Padanilam Mathew, J Patel Parin, N Prystowsky Eric, K Ravichandra Ashwinn. Rate Control Versus Rhythm Control in Patients with Left Ventricular Assist Devices and Atrial Fibrillation.. Journal of atrial fibrillation. 2021. DOI: 10.4022/jafib.20200474.