m+Medelevator.RU
← Поиск публикаций
Cureus · 2021

Stereotactic Radiosurgery for Atrioventricular Node Ablation in Swine: A Study on Efficacy and Dosimetric Evaluation of Organs at Risk.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ramia Paul, Ollaik Farah, Hilal Lara, Jalbout Wassim, AlJaroudi Wael, Al Ahmad Amin, Sfeir Pierre, Jurjus Abdo, Refaat Marwan, Youssef Bassem

Аннотация

Introduction Stereotactic radiosurgery (SRS) delivered to arrhythmogenic foci within the heart is a promising treatment modality. We dosimetrically evaluated the radiation dose to the organs at risk of four swine that were successfully treated with linear-accelerator-based SRS for atrioventricular (AV) node ablation. Materials and methods Single-chamber pacemakers were implanted in four large white breed swine. Cardiac computed tomography simulation scans were performed to localize the AV node and organs at risk. SRS (35-40 Gy) was delivered to the AV node, and the pigs were followed up with pacemaker interrogations. One-sample t-tests were used to evaluate Dmax of great vessels, esophagus, and chest wall as compared to known normal tissue constraints as per RTOG 0631 and AAPM Task Group 101. Results All pigs had disturbances of AV conduction with progressive transition into complete heart block. Macroscopic and microscopic evaluation showed fibrosis in the AV node but did not reveal any changes in non-nodal cardiac tissue or vessels. The mean Dmax±SD (p-value) of the chest wall (14.7±3.3 (0.02)), esophagus (10.7±1.1 (<0.01)) superior vena cava (3.3±4.1 (<0.01)), right pulmonary artery (16.1±6.4 (<0.01)), right pulmonary vein (15.7± 5 (<0.01)), left pulmonary artery (11.1±1.7 (<0.01)) and left pulmonary vein (14.1±2.6 (<0.01)), and the inferior vena cava (33.68±1.6 (0.026)) were significantly below the normal tissue constraint cutoffs. Mean±SD (p-value) of the ascending aorta (19.4±16.1 (0.12)) was not significantly different than normal tissue constraint cutoffs. One swine model treated at 40 Gy had small area of hotspot in the ascending aorta (40.65 (0.4 cc)). Conclusion We have demonstrated in our swine models that SRS using 35-40 Gy can be done without exceeding known human normal tissue constraints to the chest wall, esophagus, and great vessels.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты