DOI 10.1161/jaha.121.022217

Медицинская библиотека · Journal of the American Heart Association · 2021

Assessment of an ECG-Based System for Localizing Ventricular Arrhythmias in Patients With Structural Heart Disease.

Zhou Shijie, AbdelWahab Amir, Sapp John L, Sung Eric, Aronis Konstantinos N, Warren James W, MacInnis Paul J, Shah Rushil, Horáček B Milan, Berger Ronald, Tandri Harikrishna, Trayanova Natalia A, Chrispin Jonathan

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Background We have previously developed an intraprocedural automatic arrhythmia-origin localization (AAOL) system to identify idiopathic ventricular arrhythmia origins in real time using a 3-lead ECG. The objective was to assess the localization accuracy of ventricular tachycardia (VT) exit and premature ventricular contraction (PVC) origin sites in patients with structural heart disease using the AAOL system. Methods and Results In retrospective and prospective case series studies, a total of 42 patients who underwent VT/PVC ablation in the setting of structural heart disease were recruited at 2 different centers. The AAOL system combines 120-ms QRS integrals of 3 leads (III, V2, V6) with pace mapping to predict VT exit/PVC origin site and projects that site onto the patient-specific electroanatomic mapping surface. VT exit/PVC origin sites were clinically identified by activation mapping and/or pace mapping. The localization error of the VT exit/PVC origin site was assessed by the distance between the clinically identified site and the estimated site. In the retrospective study of 19 patients with structural heart disease, the AAOL system achieved a mean localization accuracy of 6.5±2.6 mm for 25 induced VTs. In the prospective study with 23 patients, mean localization accuracy was 5.9±2.6 mm for 26 VT exit and PVC origin sites. There was no difference in mean localization error in epicardial sites compared with endocardial sites using the AAOL system (6.0 versus 5.8 mm, P=0.895). Conclusions The AAOL system achieved accurate localization of VT exit/PVC origin sites in patients with structural heart disease; its performance is superior to current systems, and thus, it promises to have potential clinical utility.

Для цитирования: Zhou Shijie, AbdelWahab Amir, Sapp John L, Sung Eric, Aronis Konstantinos N, Warren James W, MacInnis Paul J, Shah Rushil, Horáček B Milan, Berger Ronald, Tandri Harikrishna, Trayanova Natalia A, Chrispin Jonathan. Assessment of an ECG-Based System for Localizing Ventricular Arrhythmias in Patients With Structural Heart Disease.. Journal of the American Heart Association. 2021. DOI: 10.1161/jaha.121.022217.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.