MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3857/roj.2021.00276

Медицинская библиотека · Radiation oncology journal · 2021

Tailored stereotactic radiotherapy technique using deep inspiration breath-hold to reduce stomach dose for cardiac radioablation.

Cha Myung-Jin, Cuculich Phillip S, Robinson Clifford G, Chang Ji Hyun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To provide a new insight on a novel safe cardiac radioablation using deep inspiration breath-hold (DIBH) to reduce gastrointestinal dose.

MATERIALS AND

METHODS

For treating incessant ventricular tachycardia (VT) originated from left ventricle inferior scar abutting the stomach, a target delineation and treatment planning for cardiac radioablation was performed. With four different computed tomography (CT) scan protocols-DIBH, full expiration breath-hold, four-dimensional (4D) CT without and with abdominal compression, the distances between the target and the stomach were compared.

RESULTS

Among the protocols, the CT scan with DIBH showed largest distance between the target and the stomach and selected for the treatment planning. The prescribed dose was 25 Gy in a single fraction, and satisfactory dosimetric parameters were achieved with the DIBH. The patient was successfully treated with the DIBH, and experienced no acute toxicity.

CONCLUSION

To gain the best benefit from cardiac radioablation, understanding the possible toxicity in the adjacent organs is crucial. By moving the heart with thoraco-diaphragmatic movement by DIBH, the target could be physically separated from the stomach.

Для цитирования: Cha Myung-Jin, Cuculich Phillip S, Robinson Clifford G, Chang Ji Hyun. Tailored stereotactic radiotherapy technique using deep inspiration breath-hold to reduce stomach dose for cardiac radioablation.. Radiation oncology journal. 2021. DOI: 10.3857/roj.2021.00276.