DOI 10.1016/s1078-5884(96)80252-8
Accuracy of duplex sonography before carotid endarterectomy--a comparison with angiography.
Аннотация
OBJECTIVES
The aim of this prospective study was to contribute to the evaluation of the reliability of Duplex sonography (DS) before carotid endarterectomy (CEA).
DESIGN
The study was performed prospectively in a university hospital setting.
METHODS
Eighty-one consecutive patients aged 49-83 years were examined with DS and carotid angiography (CAG) before CEA. The results of the DS were judged as either confident, or CAG was assessed to be necessary preoperatively. The results from the DS and the CAG were then compared.
RESULTS
DS was judged as confident in 148 of the 162 arteries examined. In none of these 148 arteries did CAG change patient management in any way, and the agreement between DS and CAG was good. In the remaining 14 arteries CAG was judged necessary, in 11 arteries because DS assessed the internal carotid artery (ICA) as occluded, which was confirmed by CAG in 10 arteries. In three arteries the reason was poor quality of the DS, however these three arteries were correctly assessed as severely diseased.
CONCLUSIONS
This study confirms that DS alone is sufficient in the preoperative evaluation before CEA, provided that CAG is performed whenever DS shows occlusion of the ICA, or when the quality of the DS is poor.