MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1078-5884(96)80131-6

Медицинская библиотека · European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 1996

Detection of sub-critical arterial stenoses by hyperaemic Doppler.

Currie I C, Wilson Y G, Baird R N, Lamont P M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study assessed the potential of hyperaemic Doppler to detect sub-critical stenoses using a flowrig model.

METHODS

Pulsatile flow of a blood substitute was produced in a compliant circuit. A cadaver carotid artery, constricted by a silk suture produced a variable, focal stenosis. Forty-seven stenoses were created in five arteries. Pressure gradients and Doppler measurements were recorded simultaneously across each stenosis at low (200 ml/min) and high (400 ml/min) flow rates. The change in peak velocities between the arterial segment 2cm proximal to the stenosis (V1), and the stenotic jet (V2) were used to calculate three Doppler indices: (i) V2/V1 ratio, (ii) V2-V1 difference, (iii) a modified 'Bernoulli' value. A high flow pressure gradient of > or = 15% of the resting distal pressure (% delta P), represented a significant stenosis.

RESULTS

There was improved correlation between Doppler indices and % delta P at high flow (r = 0.87 to 0.88) compared to low flow rates (r = 0.81 to 0.84). Optimum V2/V1 cut off values were determined by received operator characteristics (ROC) curve analysis. At low flow five sub-critical stenoses were not detected (sensitivity 82.8%) yet all but one of these lesions were identified at high flow (sensitivity of 96.6%). The V2-V1 and Bernoulli indices did not improve on the discriminant ability of the V2/V1 ratio.

CONCLUSIONS

The V2/V1 ratio is sensitive to haemodynamic changes at enhanced flow rates across ideal arterial stenoses. The potential of hyperaemic Doppler to detect sub-critical lesions and so avoid intraarterial pressure measurements deserves further in vivo study.

Для цитирования: Currie I C, Wilson Y G, Baird R N, Lamont P M. Detection of sub-critical arterial stenoses by hyperaemic Doppler.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 1996. DOI: 10.1016/s1078-5884(96)80131-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.