MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-9610(99)80276-1

Медицинская библиотека · American journal of surgery · 1995

Detection of total occlusion, string sign, and preocclusive stenosis of the internal carotid artery by color-flow duplex scanning.

Mansour M A, Mattos M A, Hood D B, Hodgson K J, Barkmeier L D, Ramsey D E, Sumner D S

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Stroke prevention depends on the accurate differentiation of surgically treatable preocclusive lesions from total occlusions of the internal carotid artery. This prospective study was undertaken to review the accuracy of colorflow duplex scanning for identifying carotid string signs, focal preocclusive lesions (95% to 99% stenoses), and total occlusion of the internal carotid artery.

MATERIALS AND

METHODS

Over an 18-month period, 4,362 patients underwent color-flow duplex scanning of the carotid arteries. Angiograms of 596 internal carotid arteries were available for comparison with the duplex scan findings. Total occlusion was diagnosed by the absence of flow in internal carotid arteries visualized on B-mode scanning. Preocclusive lesions were identified by a trickle of flow in the vessel lumen.

RESULTS

Of 65 color-flow duplex scans that predicted total occlusion, 64 (98%) were confirmed by angiography. The negative predictive value for total occlusion was 99%. Twenty-six (87%) of 30 string signs and focal 95% to 99% stenoses were correctly identified. Color-flow scanning prediction of preocclusive lesions was accurate in 84% of 31 cases. Low velocities in the internal carotid artery were usually associated with a string sign, and high velocities with a focal preocclusive lesion.

CONCLUSIONS

Color-flow duplex scanning accurately differentiates between stenotic and totally occluded internal carotid arteries. Identification of preocclusive lesions is not as accurate but the results are promising. Arteriographic confirmation of duplex scan findings is necessary only when scans are equivocal.

Для цитирования: Mansour M A, Mattos M A, Hood D B, Hodgson K J, Barkmeier L D, Ramsey D E, Sumner D S. Detection of total occlusion, string sign, and preocclusive stenosis of the internal carotid artery by color-flow duplex scanning.. American journal of surgery. 1995. DOI: 10.1016/s0002-9610(99)80276-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.