DOI 10.1097/00004728-199409000-00003
Quantification of carotid blood flow velocity using MR phase mapping.
Аннотация
OBJECTIVE
The purpose of this study was to determine the feasibility of a two-dimensional phase-sensitive MR technique [phase mapping (PM)] for the quantification of carotid blood flow velocity (CBFV) and pulsatility in normal subjects and patients with extracranial carotid disease.
MATERIALS AND
METHODS
Using PM, we measured the systolic peak, minimum diastolic, and mean CBFV and the pulsatility index in both common carotid arteries (CCAs) of 22 normal subjects and 32 patients. In addition, the CBFV was quantified in the internal carotid arteries (ICAs) of 25 patients. These data were compared with independent measurements based on pulsed-wave Doppler ultrasonography.
RESULTS
Correlations between PM and pulsed-wave Doppler were strong for systolic peak CBFV in both the CCA (r = 0.91) and the ICA (r > or = 0.82). Slightly lower correlations were obtained for mean CBFV (r > or = 0.79) and minimum diastolic CBFV (r > or = 0.75), both measured in the CCA. Velocity waveform comparison revealed high between-method correlations for the CCA (r = 0.90 for normals; r > or = 0.88 for patients) and slightly lower correlations for the ICA (r > or = 0.75). Agreement was lower (r = 0.63) for measurements in the ICA distal to high grade stenosis.
CONCLUSION
Phase mapping compared well with Doppler ultrasonography in quantifying CBFV and pulsatility in patients with extracranial carotid artery disease. Except for poststenotic measurements in high grade obstructive lesions, PM is capable of providing quantitative hemodynamic information on the severity of ICA stenosis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.