Generating synthetic contrast enhancement from non-contrast chest computed tomography using a generative adversarial network.

Choi Jae Won, Cho Yeon Jin, Ha Ji Young, Lee Seul Bi, Lee Seunghyun, Choi Young Hun, Cheon Jung-Eun, Kim Woo Sun

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This study aimed to evaluate a deep learning model for generating synthetic contrast-enhanced CT (sCECT) from non-contrast chest CT (NCCT). A deep learning model was applied to generate sCECT from NCCT. We collected three separate data sets, the development set (n = 25) for model training and tuning, test set 1 (n = 25) for technical evaluation, and test set 2 (n = 12) for clinical utility evaluation. In test set 1, image similarity metrics were calculated. In test set 2, the lesion contrast-to-noise ratio of the mediastinal lymph nodes was measured, and an observer study was conducted to compare lesion conspicuity. Comparisons were performed using the paired t-test or Wilcoxon signed-rank test. In test set 1, sCECT showed a lower mean absolute error (41.72 vs 48.74; P < .001), higher peak signal-to-noise ratio (17.44 vs 15.97; P < .001), higher multiscale structural similarity index measurement (0.84 vs 0.81; P < .001), and lower learned perceptual image patch similarity metric (0.14 vs 0.15; P < .001) than NCCT. In test set 2, the contrast-to-noise ratio of the mediastinal lymph nodes was higher in the sCECT group than in the NCCT group (6.15 ± 5.18 vs 0.74 ± 0.69; P < .001). The observer study showed for all reviewers higher lesion conspicuity in NCCT with sCECT than in NCCT alone (P ≤ .001). Synthetic CECT generated from NCCT improves the depiction of mediastinal lymph nodes.

Для цитирования: Choi Jae Won, Cho Yeon Jin, Ha Ji Young, Lee Seul Bi, Lee Seunghyun, Choi Young Hun, Cheon Jung-Eun, Kim Woo Sun. Generating synthetic contrast enhancement from non-contrast chest computed tomography using a generative adversarial network.. Scientific reports. 2021. DOI: 10.1038/s41598-021-00058-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.