Scaffold thrombosis following implantation of the ABSORB BVS in routine clinical practice: Insight into possible mechanisms from optical coherence tomography.

Kraak Robin P, Kajita Alexandre H, Garcia-Garcia Hector M, Henriques Jose P S, Piek Jan J, Arkenbout E Karin, van der Schaaf René J, Tijssen Jan G P, de Winter Robbert J, Wykrzykowska Joanna J

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

To identify potential underlying mechanisms of early and (very) late scaffold thrombosis (ScT) by optical coherence tomography (OCT), in a frame-by-frame analysis.

BACKGROUND

The absorb scaffold is associated with an increased risk of ScT compared with metallic stents. Several potential causes of bioresorbable ScT have been identified, however the precise etiology still remains unclear.

METHODS

Between February 2013 and February 2016, 13 patients presenting with definite ScT underwent OCT imaging. After guidewire passage or balloon inflations, OCT images were acquired. Pullbacks were assessed offline at each 1 mm longitudinal interval within the treated segment and the 5 mm segments adjacent to both edges. Primary cause of ScT was assessed by reviewing medical records, baseline angiographic films, and OCT pullback and angiographic films at time of ScT.

RESULTS

13 patients, with 14 thrombotic lesions presented either with early ScT (i.e., ≤30 days) or very (late) (i.e., >30 days). Analysis demonstrated a significantly smaller in-scaffold maximal lumen diameter in the early cases (2.75 ± 0.85 mm vs. 3.00 ± 0.46 mm; P = 0.033) and a nonsignificant smaller minimal scaffold diameter (2.44 ± 0.62 mm vs. 2.58 ± 0.37 mm P = 0.097). Per-strut analysis demonstrated significantly more malapposed scaffold struts in (very) late cases (6% versus 0.6%, P < 0.001). Assessment of the predominate cause showed underexpansion as the dominant factor in the early cases, while malapposition was predominantly seen in the (very)late cases.

CONCLUSIONS

OCT performed in patients presenting with Absorb ScT demonstrated that malapposition of scaffold struts was more prominent in patients presenting with (very) late ScT, while underexpansion was more frequent in the early cases.

Для цитирования: Kraak Robin P, Kajita Alexandre H, Garcia-Garcia Hector M, Henriques Jose P S, Piek Jan J, Arkenbout E Karin, van der Schaaf René J, Tijssen Jan G P, de Winter Robbert J, Wykrzykowska Joanna J. Scaffold thrombosis following implantation of the ABSORB BVS in routine clinical practice: Insight into possible mechanisms from optical coherence tomography.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2018. DOI: 10.1002/ccd.27475.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.