MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/joic.12469

Медицинская библиотека · Journal of interventional cardiology · 2017

Comparison of clinical outcomes of coronary artery stent implantation in patients with end-stage chronic kidney disease including hemodialysis for three everolimus eluting (EES) stent designs: Bioresorbable polymer-EES, platinum chromium-EES, and cobalt chrome-EES.

Sato Takao, Hatada Katsuharu, Kishi Syohei, Fuse Koichi, Fujita Satoshi, Ikeda Yoshio, Takahashi Minoru, Matsubara Taku, Okabe Masaaki, Aizawa Yoshifusa

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUNDS: New-generation bioresorbable polymer-everolimus eluting stents (BP-EES) are available. This study aimed to compare the clinical outcomes for BP-EES compared to more established stent designs, namely the platinum chromium-EES (PtCr-EES) and cobalt chrome-EES(CoCr-EES) in patients with the end-stage chronic kidney disease (CKD) including hemodialysis (HD).

METHODS

One-hundred-forty-one consecutive stents (BP-EES [n = 44], PtCr-EES [n = 45], and CoCr-EES [n = 52]) were implanted in 104 patients with CKD. All patients underwent a follow-up coronary angiography at 12 months after implantation. End-stage CKD was defined as an estimated glomerular filtration rate (eGFR) <30 mL/min/1.73 m2 , or the need for HD. The following outcome variables were compared among the three stent groups after implantation and the 12-month follow-up: target lesion revascularization (TLR), stent thrombosis (ST), and major adverse cardiac event (MACE). Minimal stent diameter (MSD) and %diameter-stenosis (%DS) were measured using quantitative coronary angiography.

RESULTS

The overall rate of TLR and MACE was 14.6% and 30.8%, respectively, with no incidence of ST. Immediately after implantation, the MSD (P = 0.22) and %DS (P = 0.42) were equivalent among the three groups. However, at the 12-month follow-up, a tendency towards higher TLR was observed for the BP-EES group (22.7%) compared with the PtCr-EES (8.8%) and CoCr-EES (9.6%) groups (P = 0.07). Late loss in lumen diameter was also significantly greater for the BP-EES (0.51 ± 0.64 mm) group than either the PtCr-EES (0.20 ± 0.61 mm) and CoCr-EES (0.25 ± 0.70 mm) groups (P = 0.03).

CONCLUSIONS

BP-EES might increase the risk of in-stent restenosis in patients with end-stage of CKD or the need for HD.

Для цитирования: Sato Takao, Hatada Katsuharu, Kishi Syohei, Fuse Koichi, Fujita Satoshi, Ikeda Yoshio, Takahashi Minoru, Matsubara Taku, Okabe Masaaki, Aizawa Yoshifusa. Comparison of clinical outcomes of coronary artery stent implantation in patients with end-stage chronic kidney disease including hemodialysis for three everolimus eluting (EES) stent designs: Bioresorbable polymer-EES, platinum chromium-EES, and cobalt chrome-EES.. Journal of interventional cardiology. 2017. DOI: 10.1111/joic.12469.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.