DOI 10.14309/crj.0000000000001831
Lumen-Apposing Metal Stent Bleeding Risk: Management of Splenic Artery Erosion.
Аннотация
Lumen-apposing metal stents (LAMS) have been used for drainage of peripancreatic collections, although they may be associated with complications, including bleeding. We report a case of a 49-year-old male patient who developed hematemesis and syncope three and a half weeks after LAMS placement for peripancreatic collection drainage. A computed tomography scan revealed splenic artery erosion by the distal flange of the stent. Splenic artery embolization was performed before LAMS removal, and splenectomy was required 3 days later. The patient remains asymptomatic after two years of follow-up. This case demonstrates an approach to a rare but potentially fatal complication of LAMS.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.