MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.surg.2006.07.031

Медицинская библиотека · Surgery · 2006

Radionuclide imaging for hyperparathyroidism (HPT): which is the best technetium-99m sestamibi modality?

Sharma Jyotirmay, Mazzaglia Peter, Milas Mira, Berber Eren, Schuster David M, Halkar Raghuvee, Siperstein Alan, Weber Collin J

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To determine the utility of available radionuclide imaging modalities for preoperative parathyroid localization, we compared the accuracy of 4 types of technetium-99m ((99)Tc) sestamibi-based scans.

METHODS

Over 5 years, 833 patients with sporadic primary hyperparathyroidism underwent either (99)Tc-sestamibi with planar views (Planar; n = 138); sestamibi single photon emission computed tomography (SPECT; n = 165); SPECT with thyroid (123)I-subtraction phase (SPECT/(123)I; n = 350); or SPECT combined with conventional CT (SPECT/CT; n = 180). The accuracy of each modality was determined on the basis of intraoperative parathyroid pathology, defined as single adenoma or multigland disease.

RESULTS

Planar scans had significantly more false negatives (no tumor visualized) than SPECT-based scans (P < 0.01), but positive predictive values were similar. A false-negative scan was present in 38% of Planar scans, 27% SPECT, 4% SPECT/(123)I, and 17% SPECT/CT, with single adenoma found at operation in 77%, 64%, 53%, and 74%, respectively. When a scan had a single focus of uptake, SA was found at that location in 77%, 85%, 68%, and 87%, respectively. SPECT, SPECT/(123)I, and SPECT/CT did not significantly reduce the false-positive rate.

CONCLUSIONS

We recommend obtaining multiplanar SPECT-based imaging, which offers 3-dimensional localization and improved detection of parathyroid tumors when compared with Planar scans. A negative scan did not predict multigland disease.

Для цитирования: Sharma Jyotirmay, Mazzaglia Peter, Milas Mira, Berber Eren, Schuster David M, Halkar Raghuvee, Siperstein Alan, Weber Collin J. Radionuclide imaging for hyperparathyroidism (HPT): which is the best technetium-99m sestamibi modality?. Surgery. 2006. DOI: 10.1016/j.surg.2006.07.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.