INTRODUCTION

Delayed intraparenchymal hemorrhage is a known complication of the Pipeline Embolization device (PED); however, its etiology is unclear and some have suggested it is a flow related phenomenon. Quantitative magnetic resonance angiography (QMRA) serves as a powerful tool to collect and analyze hemodynamic data. We report a detailed characterization of short-term hemodynamics after PED placement.

METHODS

Patients who underwent PED placement for a distal internal carotid artery (ICA) aneurysm between 2017 to 2019 with post embolization QMRA were reviewed. Aneurysm characteristics, flow volume rate (ml/min), mean, systolic, and diastolic flow velocities (cm/s), vessel diameter (mm), pulsatility index, Lindegaard ratio, and wall shear stress (WSS) were collected.

RESULTS

A total of 67 patients were included. Post-procedure patients were found to have a significantly lower ICA flow on the side with flow diversion when compared to the side without flow diversion (218 vs. 236.3; P < 0.05). Average ICA flow after flow diversion for aneurysms >2 cm was significantly lower when compared to the untreated side (187.7 vs. 240.4; P < 0.05). There was no difference in MCA or ACA flow or velocity. WSS was significantly lower in the treated ICA (8.2 vs. 9.0; P < 0.05). Lindegaard ratio was not different in the treated vs. contralateral untreated sides.

CONCLUSION

PED placement for distal ICA aneurysms results in lower flow, mean velocity, and WSS when compared to the contralateral untreated ICA. This is not demonstrated distal to the Pipeline device in the ACA or MCA territories. Ultimately these findings suggest hemodynamic changes are not a cause of PED complications.

Для цитирования: White Timothy G, Ryu Brendan, Shah Kevin A, Turpin Justin, Black Karen, Link Thomas, Dehdashti Amir R, Katz Jeffrey M, Woo Henry H. Quantitative magnetic resonance angiography to assess post embolization hemodynamics following pipeline embolization.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2021. DOI: 10.1177/15910199211023650.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.