Mediastinal perigraft seroma after thoracic aortic surgery.

Suzuki Ryo, Akita Masafumi, Miyazaki Suguru, Shimano Ryo

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We investigated pertinent factors associated with mediastinal perigraft seroma (PGS) after thoracic aortic surgery. In addition, we provided a clinical review of this entity, as reports reviewing abundant mediastinal PGS cases are rare.

METHODS

Eighty-two patients who underwent either ascending aortic replacement or aortic arch replacement between 2016 and 2022 in our institution were enrolled in the present study. Postoperative computed tomography scans were performed to detect fluid capsules with a diameter ≥3.0 cm and radiodensity ≤25 Hounsfield units. Patients who did and who did not develop PGS formation were compared. Variables with a statistically significant difference between these groups were included in a multiple logistic regression analysis along with other factors associated with PGS in the literature.

RESULTS

The incidence rate of PGS was 14.6% (12/82). The average radiodensity of the mass was 16.6 ± 6.3 Hounsfield units. The average onset of PGS was 8.5 months post-surgery. Multivariate logistic regression analysis revealed that ejection fraction [odds ratio (OR): 1.25, 95% confidence interval (CI): 1.03-1.50, P = 0.021], aortic dissection (versus degenerative aortic aneurysm) (OR: 6.61, 95% CI: 1.35-32.4, P = 0.02) and warfarin use (OR: 6.67, 95% CI: 1.19-37.1, P = 0.03) significantly contributed to mediastinal PGS after thoracic aortic surgery.

CONCLUSIONS

High ejection fraction, warfarin use and aortic dissection (versus degenerative aortic aneurysm) contributed significantly to mediastinal PGS formation after thoracic aortic surgery. Careful serial postoperative imaging studies and fluid analysis can be used to guide treatment plans.

CLINICAL TRIAL REGISTRATION: UMIN-CTR (University hospital Medical Information Network-Clinical Trial Registry) Registration number: UMIN000050764.

Для цитирования: Suzuki Ryo, Akita Masafumi, Miyazaki Suguru, Shimano Ryo. Mediastinal perigraft seroma after thoracic aortic surgery.. Interdisciplinary cardiovascular and thoracic surgery. 2023. DOI: 10.1093/icvts/ivad148.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.