MedElevator Войти в исследования
← Поиск публикаций

DOI 10.36660/abc.20220939

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2023

Factors Affecting False Lumen Thrombosis In Type B Aortic Dissection.

Tang Qian-Hui, Chen Jing, Yang Han, Qin Zhong, Lin Qiu-Ning, Qin Xiao

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Complete thrombosis of the false lumen facilitates remodeling of type B aortic dissection (TBAD). Morphological characteristics affect thrombosis in the false lumen.

OBJECTIVES

Discuss the factors present before admission that influence false lumen thrombosis in patients with TBAD.

METHODS

We studied 282 patients diagnosed with TBAD in our hospital between January 2008 and December 2017. We divided the subjects into a thrombotic group and a non-thrombotic group based on whether any thrombus was detectable in the false lumen. We analyzed the differences between the two groups with respect to clinical data, the vertical length of the dissection, and the diameter of the aorta. P values < 0.05 were considered statistically significantly different.

RESULTS

Significant differences between the thrombotic group and non-thrombotic group were found with respect to age (53.92 ± 11.40 vs. 50.36 ± 10.71, p = 0.009) and proportion of patients with renal insufficiency (7.83% vs. 16.38%, p = 0.026). In zones 3-9, the true lumen diameter of the thrombotic group was significantly larger than in the non-thrombotic group (p < 0.05). Binary logistic regression analysis showed that true lumen diameter in zone 5 and renal insufficiency were independent predictors of false lumen thrombosis.

CONCLUSIONS

Age and renal function were associated with thrombosis in the false lumen. Potentially, the difference between the diameter of the true lumen diameter and that of the false lumen may influence the thrombosis of the false lumen.

Для цитирования: Tang Qian-Hui, Chen Jing, Yang Han, Qin Zhong, Lin Qiu-Ning, Qin Xiao. Factors Affecting False Lumen Thrombosis In Type B Aortic Dissection.. Arquivos brasileiros de cardiologia. 2023. DOI: 10.36660/abc.20220939.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.