MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00059-017-4622-x

Медицинская библиотека · Herz · 2017

Transcatheter aortic valve replacement with balloon-expandable valve : Analysis of initial experience in China.

Shen Y, Zhang H, Zhang L, Li H, Mao H, Pei Y, Jing Z, Lu Q

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) is widely applied for the treatment of severe aortic stenosis (AS) in developed countries; however, in China, it is still in the early stage of utilization. On the basis of previous studies, this work explored the feasibility of TAVR in patients with severe AS in China and analyzed the cause of death in four cases.

METHODS

This retrospective study included 20 patients who had severe AS and underwent TAVR with a balloon-expandable system (Edwards SAPIEN XT) in our hospital from January 2011 to June 2016. The valve and heart functions of 16 survivors before and after the TAVR procedure were compared. TAVR endpoints, device success, and adverse events were assessed according to the definitions of the Valve Academic Research Consortium-2 (VARC-2).

RESULTS

There were 13 male and seven female patients aged 65-81 years (average, 73.15) who underwent TAVR. The TAVR approach was transfemoral in 19 patients and transapical in one patient. Four patients died (two of coronary artery occlusion and two of aortic annulus rupture) during the TAVR procedure or shortly after; six patients had mild paravalvular leakage, and the rest of the patients showed a significant improvement in cardiac function. During the follow-up period (2-62 months), one patient died of lung cancer 13 months after the TAVR procedure.

CONCLUSION

TAVR with a balloon-expandable system is safe and effective and can be used for patients with severe AS in China. It requires careful patient selection and preoperative assessment so as to reduce the 30-day postoperative mortality rate.

Для цитирования: Shen Y, Zhang H, Zhang L, Li H, Mao H, Pei Y, Jing Z, Lu Q. Transcatheter aortic valve replacement with balloon-expandable valve : Analysis of initial experience in China.. Herz. 2017. DOI: 10.1007/s00059-017-4622-x.