Should sinus of Valsalva be preserved in patients with bicuspid aortic valve and aortic dilation?
Аннотация
BACKGROUND
It is recommended that dilated ascending aortas (≥45 mm) should be replaced at the time of aortic valve replacement (AVR) for bicuspid aortic valve (BAV). The risk of progressive sinus of Valsalva dilatation after AVR and ascending aorta replacement is less clear.
METHODS
We identified 156 patients (age 56.2±10.8 years, 46 females) who underwent AVR and ascending aorta replacement in our institution from 2010-2014, 124 (79%) of whom had BAV. Aortic root and ascending aorta sizes were determined from preoperative and the most recent echocardiograms. The mean follow-up time was 34.4±22.3 months, and 97% of patients completed the follow-up.
RESULTS
The operative mortality rate was 1.3%. During a follow-up of up to 75.2 months, there were no late reoperations for aortic root dissection or rupture. The mean preoperative aortic root diameters in the tricuspid aortic valve (TAV) and BAV groups were 42.2±5.4 and 37.5±5.4 mm, respectively (P=0.69). After operation, most of the patients had reduced aortic root sizes, as the mean postoperative root diameters in the TAV and BAV groups were 39.6±5.2 and 35.7±5.1 mm, respectively (P=0.99).
CONCLUSIONS
To avoid the risks associated with aortic root replacement, it is reasonable to spare the aortic roots in the setting of AVR and ascending aorta replacement for BAV with a dilated ascending aorta and relatively normal sinuses of Valsalva.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.